Top Load Dryer Specifications

Product Shipping Weight (approx.) – 143 Lbs.

Designed for HOME USE only, not recommended for commercial

application.

An electrical supply with grounded three-prong receptacle is

required. The power supply circuit must be installed in accordance

with current edition of National Electrical Code (ANSI/NFPA 70)

and local codes & ordinances. (Do not use same circuit as washer.)

Voltage Rating – 120V / 60 Hz / 15 Amps

Amps @ 120 Volts = 9.0 Amps

Connected Load (kW Rating) @ 120 Volts = 1.0 kW

Equipped with 120V 3-wire power supply cord, approx. 60" long.

Always consult local and national electric & gas codes.

Dryer can be installed in recess or closet requiring 0" minimum

installation clearance around sides and back of unit. To achieve 0"

minimum rear clearance, dryer MUST be vented straight back. Closet

installation requires additional 1" minimum clearance between front of

unit and vented door. Door MUST be vented with 120 sq. in. minimum

louvered opening, equally divided, located 3" from top and bottom

of door. A louvered door with equivalent air openings for full-length

of door is acceptable. Air openings MUST remain unobstructed with

door installed. (For additional installation details, refer to Product

Installation Guide on web.)

Do NOT install in area exposed to dripping water or outdoor weather

conditions; where gasoline or other flammables are kept or stored; or

where dryer comes in contact with curtains, drapes or anything that

will obstruct flow of combustion and ventilation air.

For garage installation, dryer MUST be located minimum 18" above floor.

Floor MUST be solid with 1" maximum slope. Do NOT install on

carpeted surface.

Dryer MUST exhaust to outside of building, NOT into any concealed

space.

Exhaust installation requires minimum 4"-diameter rigid or semi-rigid

metal duct with approved, unobstructed vent hood having swing-out

damper(s). If installing rigid metal duct (preferred), do not exceed

MAXIMUM venting run length of 64 ft., allow deductions for elbows

and vents. If installing semi-rigid metal duct, do not exceed MAXIMUM

venting run length of 8 ft., always allow deductions for elbows and

vents (Refer to Product Installation Guide on web for additional

information). Do NOT use flexible plastic or metal foil duct and use

shortest run possible.

Gas supply line should be 1/2" pipe and MUST have individual

shutoff valve.

Leveling legs supplied to level dryer properly and reduce excessive

noise and vibration.

For manufactured or mobile home installation optional Mobile Home

Installation Kit (PN # 137067200) required. (For specific installation

details, refer to Product Installation Guide on web.)

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Mobile Home Installation Kit – (PN # 137067200).

LP Gas Conversion Kit – (PN # PCK4200).

Drying Rack – (PN # 137067300).

Specifications

subject to change.

Top Load Laundry - Gas Dryer

Frigidaire Affinity (M models)

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-800-FRIGIDAIRE

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

FARG1011M 09/13

© 2013 Electrolux Home Products, Inc.

Dryer

FARG1011MW

7.0 Cu. Ft. D.O.E. Gas

Advertising