Stainless chimney wall-mount hood, Electrolux major appliances, n.a – FRIGIDAIRE RH30WC55GS User Manual

Page 2

Advertising
background image

Stainless Chimney Wall-Mount Hood

RH30WC55G S

High standards of quality at Electrolux Home Products, Inc. mean

we are constantly working to improve our products. We reserve the right

to change specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-877-4electrolux (1-877-435-3287)

electroluxappliances.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxappliances.ca

RH30WC55G 04/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.

30" Stainless Chimney
Wall-Mount Hood Specifications

Product Weight – 36 Lbs.

Wall-Mount Installation

Ventilation system is preset to exhaust air outside. If outside ducting is
not possible, optional Duct-Free Kit (PN # RHDFW60GS) is available to
convert ventilation to allow air to recirculate inside. (Refer to Ducted
Option Specifications for outside ventilation.)

Sones Rating – 9.0

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.475 kW (For use on
adequately wired 120V, dedicated circuit having 2-wire service with a
separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 3.84 Amps

Always consult local and national electric codes. Check local
building codes for installation requirements, as they may vary per locale.

Minimum installation height allowed from bottom of hood to cooking
surface is 24" - 30" for electric and 30" for gas. (NOT more than 36"
recommended.)

To prepare mounting surface, adequate structure and support must be
provided, capable of supporting 100 lbs.

Ducted Option Specifications

For outside ventilation.

Exhaust Duct Required – 8" round

For most efficient airflow exhaust, use a straight run or as few elbows
as possible.

Use metallic flex ducting only to connect rigid duct directly to transitions
(if allowed by code).

Thermal breaks such as short section of nonmetallic duct, should
be used in areas of extreme cold.

Cold weather installations should have additional backdraft damper
installed.

Refer to installation instructions on web for detailed exhaust duct
preparation and converting vent blower system for recirculating inside.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Optional Accessories

Charcoal Filter – (PN # RHCFW60GS).

Duct-Free Kit (Single Pack) – (PN # RHDFW60GS).

52" Flue Extension – (PN # RHXWC55GS).

Controls

Top

Wiring box

Air outlet - 7

7

/

8

" diam.

4

9

/

16

"

24

5

/

8

"

min.

42

9

/

16

"

max.

5"

19

11

/

16

"

29

7

/

8

"

Dimensions
from base of
hood to ceiling,
and include
clearance
required for
installation.

24"

( min.

height

with one

cover)

13

3

/

16

"

10

11

/

16

"

Advertising