Single Wall Furnace models
may be equipped with a
Rear Register Kit and Grille
(40542) allowing warm air
to circulate into the adjoin-
ing room. Adjustable vent
controls air flow.

ROUGH IN

Easy installation method reduces installation time to
minutes . . . only one man needed. New positive fastening
tabs hold grille in place . . . makes installation a snap!

Resettable Blocked Flue
Safety Device automatically
shuts the unit off in the
event of flue blockage or
incorrect vent installation.

Continuous Seam-Welded
Combustion Chamber
constructed of heavy gauge
aluminized steel, maximizes
heat transfer. Warranted for
ten (10) years.

Free Standing Kit (FSK)
allows single wall furnaces
to be surface mounted.
Eliminates cutting holes in
wall — ideal for masonry
wall installation. For use
with ceilings up to 8'6" tall;
adds 4-3/4" to unit depth.
(vent pipe not included).
Weight: 16 lbs.

Fan accessory kit (WFF81)
available for installation on
top of furnace to increase
circulation. Adds only 10

1

/

2

to height of casing. Fits
flush against wall — not
recessed. Operates at
50 CFM on 115V.

Optional Night Setback
Thermostat (XL 110 / XL411)
provides economic as well
as convenient operation.

W251

Bulb

Nat.

25,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W255

M. Volt

Nat.

25,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W252

Bulb

L.P.

25,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W256

M. Volt

L.P.

25,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W351

Bulb

Nat.

35,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W355

M. Volt

Nat.

35,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W352

Bulb

L.P.

35,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W356

M. Volt

L.P.

35,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

90 lbs.

40542

5 lbs.

WFF81

10 lbs.

W501

Bulb

Nat.

50,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

W505

M. Volt

Nat.

50,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

134 lbs. N/A

N/A

WFF81

10

lbs.

W502

Bulb

L.P.

50,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

W506

M. Volt

L.P.

50,000

4"

1/2"

16

1

/

2

" W

68" H

6

1

/

2

" D

134 lbs.

N/A

N/A

WFF81

10 lbs.

Model

Type

Type

BTU/Hr.

Vent

Gas

Finished

Shipping

Number

Control

Gas

Input

Size

Inlet

Dimensions

Weight

Model

Weight

Model

Weight

Rear Register Kit

Fan Kit

SINGLE

WALL

One or two fan kits may be used on dual-wall furnace.

DUAL

WALL

SPECIFICATIONS

14

1

/

4

" MIN.

14

1

/

2

" MAX.

65

3

/

4

"

45

3

/

4

"

12

5

/

8

"

8

1

/

4

"

PLASTER

PLATE

REAR
REGISTER
FRAME

OPENING
FOR REAR
REGISTER
MODEL

OPENING
7/8

" FROM

EACH STUD

NAIL TO
STUDS

PLASTER

STUD

PLASTER

4

"

4

"

ROUGH-IN DIMENSIONS

REAR REGISTER OUTLET LOCATION

Form No. GWF 15M 10/05

Engineered for years of efficient, trouble free service

Featuring 20 gauge aluminized combustion chambers, warranted for 10 years.