Universal dmx control (dmx mode), Trouble shooting, Rouble – Chauvet SCORPION LRG-55 User Manual

Page 12: Hooting

Advertising
background image

Universal DMX Control (DMX Mode):

This mode allows you to use a universal DMX-512 controller to control lasers operation and effects.

1)

To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units
together via the XLR connector on the rear of the units. For long cable runs we suggest a
terminator at the last fixture.
Mode Dipswitches
DMX mode

10 = On, 11 = Off, 12 = On

2)

Assign a DMX address to the unit by following the dipswitch chart.

3)

Use DMX controller to control your units.

OUT

IN

POWER

1: DMX

2: DMX

N: DMX

DMX-512

Note!

System doesn’t use DMX controller in Master-Slave Mode.

System may not set to two Master units in Master-Slave Mode.

Trouble Shooting

1)

If the power supply indicator does not light up and the laser does not work, please check if the
power supply and the corresponding parts have the right input electric current.

2)

If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not
working, please check if the operation system is set up in Master/Slave mode.

3)

If it is in Master/Slave mode, Slave mode is exceptional, please check as below:
A. Make sure to set up Master mode for just one unit and the others are set in slave mode.
B. Make sure to control the unit with DMX controller.
C. Make sure to take a good quality power cord and connection.

4)

If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX
signal indicator is not illuminated please check as below:
A. Make sure to set up the DMX mode.
B. Make sure to have a good connection.

5)

If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal
indicator flashes, please make sure the DMX controller and the laser have the same DMX
Address.

6)

If the no laser outputs from the projector please restart the AC power by turning off the AC
switch and leaving off for 15 seconds and then turning the switch back to the on position.

7)

If the test pattern is not in the proper position restart the AC power by turning off the AC switch
and leaving off for 15 seconds and then turning the switch back to the on position.

After trying the above solution you still have a problem, please contact CHAUVET.

LRG-55 User Manual

12

11/14/2007/18:46

Advertising