5

UVS27 Vent-Free Gas Heater

20007068

Hearth Requirements

The Freestanding Stove and Hearthmount Shell must
be installed on rigid flooring. If the appliance is installed
on any combustible surface other than wood flooring,
such as carpet or tile, a metal or wood panel must be
installed to extend the full length and width of the unit.

• Do not install this heater in a bathroom or bed-

room.
• Installation of this heater must conform with local

codes or, in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1 / NFPA54.
• This heater creates warm air currents. These

currents move heat to wall surfaces next to the

heater. Installing the heater next to vinyl or cloth

wall coverings or operating the heater where im-

purities in the air such as tobacco smoke exist,

may discolor walls.
• Do not use a blower insert, heat exchanger

insert or other accessory not approved for use

with this heater.

Clearance Requirements

Minimum Clearances to

Combustible Materials

Maintain clearance, (empty space), between combus-
tible materials and the heater as specified below for the
appropriate firebox shell being installed.

WARNING

B

A

C

D

ST101

Min. Clrnc

4/15/99 djt

B

A

C

D

ST102

Min. Clrnc

4/15/99 djt

Freestanding Stove

Hearthmount

ST101

ST102

A: Mantel/Trim* .........................35” (889 mm) / 2” (51 mm)
B: Side Wall/Trim* ............................................. 2” (51 mm)
C: Rear Wall ....................................................... 0” (0 mm)
D: Max. Mantel Width ................................... 13” (330 mm)

B

A

C

D

ST103

Min. Clrnc

4/15/99 djt

B

Alcove Clearances

A: Ceiling ...................................................... 35” (889 mm)
B: Side Wall ...................................................... 2” (51 mm)
C: Rear Wall ....................................................... 0” (0 mm)
D: Max. Alcove Depth ................................... 13” (330 mm)

ST103

FP599a

stove mantel heights

9/27/99 djt

S

T

U

V

W

X

Y

Z

A

B

C

D

E

F

G

H

ST599a

Mantel

Mantel from

Ref.

Shelf Depth

Ref.

Stove Top

A

13” (330mm)

S

35” (889 mm)

B

11¹⁄₄” (286 mm)

T

30” (762 mm)

C

9³⁄₈” (241 mm)

U

25” (635 mm)

D

7¹⁄₂” (191 mm)

V

20” (508 mm)

E

5³⁄₄” (146 mm)

W

15” (381 mm)

F

4” (102 mm)

X

10” (254 mm)

G

2¹⁄₄” (57 mm)

Y

5” (127 mm)

H

1” (25 mm)

Z

2” (51 mm)