Led indicators – CyberPower Systems CPS900AVR User Manual

Page 9

Advertising
background image

CPS900AVR

Guaranteed Uninterruptible Power System



As the battery discharges, the unit will beep more rapidly, indicating that the battery is nearing discharge. Once the test is complete, plug the UPS back in to
the AC outlet and start your computer. Please allow 4 hours for the UPS to recharge before attempting another self-test.


DEFINITIONS FOR ILLUMINATED LED INDICATORS

Power

On

Wiring

Fault

AVR

Using

Battery

Check

Battery

Circuit

Breaker

Alarm

Condition

On Off

Off

Off Off Set

Off

Normal

On Off Flash

Off Off Set

Off

AVR- AVR is maintaining a consistent 120v level (±5%)

during a power sag.

ON Off

On

Off Off Set

Off

AVR- AVR is maintaining a consistent 120v (±5%)

during a power surge

Off On/Off

Off

On

Off

Set

Two

Beeps

Utility Failure- The UPS is providing battery power to

the Battery-Power Supplied outlets.

Off

On/Off

Off

On

Off

Set

Rapid Beeps

Utility Failure- The UPS is providing battery power.

The rapid beeps indicate the battery will run out of

charge within a few minutes.

Off

Off

Off

On

Off

Up

Two beeps or rapid

beeps

Overload- Occurs in the Full-time Surge Protection

Outlets. Turn the UPS off and unplug at least one

piece of equipment from the UPS. Wait 5 seconds,

reset the circuit breaker and turn the UPS on.

On/Off On/Off On/Flash/Off On/Off

Off

Set

Long

Beep

Overload- Occurs in the Battery-power Supplied

Outlets. Turn the UPS off and unplug at least one piece

of equipment from the UPS. Wait 5 seconds, reset the

circuit breaker and turn the UPS on.

Off Off

Off

On Off Up

Long

Beep

Overload- Occurs in the Battery-power Supplied

Outlets. Turn the UPS off and unplug at least one piece

of equipment from the UPS. Wait 5 seconds, reset the

circuit breaker and turn the UPS on.

On On/Off

On/Flash/Off Off

On

Set

None

Weak Battery- Recharge the battery for at least 8

hours. If Check Battery is illuminated contact

CyberPower Systems for battery replacement

information.

Off Off

Off

Off Off Set

Off

Surge Protection Malfunction- Lightning induced

power line surge has damaged the surge-protect

function. Please contact CyberPower Systems

On/Off On/Off On/Flash/Off Flash Flash

Set/Up

Off

Scheduled Turn-on- If the two battery indicators are

flashing in rotation, the UPS is waiting to turn on as

configured in the schedule.

On/Off On/Off On/Flash/Off Flash Flash

Set/Up

Three

Beeps

Cold Start Disabled- If the two battery indicators are

flashing at the same time, the cold-start has been

disabled. The UPS will not start in the absence of AC

power.

On/Off On On/Flash/Off

On/Off On/Off Set/Up

None

Electrical Wiring Fault- This indicates a wiring a
problem such as a bad ground, missed ground or

reversed wiring within the AC outlet. User is advised

to disconnect all electrical equipment from the outlet and

have the outlet checked by an electrician.



















7