ONBOARD L.E.D. INDICATOR DESCRIPTIONS

Control Board L.E.D. Indicators:

OPEN

This indicator is lit when an open signal is present. This signal can come from such devices as button
stations, radio receivers, keypads and telephone entry systems.

CLOSE

This indicator is lit when a closed signal is present. This signal typically comes from three-button stations.

STOP

This indicator is lit when there is a break in the stop circuit. Make sure there is a stop button wired in and
working properly.

SINGLE

This indicator is lit when a signal from a single-button station or radio receiver is present.

CLOSE OBST

This indicator is lit when a close obstruction signal is present. This signal can come from edges and photo
eyes which have been wired to the close obstruction inputs.

OPEN OBST

This indicator is lit when an open obstruction signal is present. This signal can come from edges and
photo eyes which have been wired to the open obstruction inputs.

SAFETY LOOP

This indicator is lit when a reversing signal is present. This signal is generated by a loop detector wired to
the safety loop terminals.

SHADOW LOOP

This indicator is lit when a shadow/hold open signal is present. This signal is generated by a loop detector
wired to the shadow loop terminals.

These indicators are lit when the open limit switch is activated on a right-hand operator, or the close switch
on a left-hand. If this indicator is lit and the gate is not in its full open/closed position, the limit may need
adjusting or the limit switch may need replacing.

These indicators are lit when the close limit switch is activated on a right-hand operator, or the open on a
left-hand. If this indicator is lit and the gate is not in its full open/closed position, the limit may need
adjusting or the limit switch may need replacing.

Motor Board L.E.D. Indicators:

NON LABELED

One of these two indicators will be lit when the motor is running the gate open, and the other is lit when the
motor is running the gate closed.

BRAKE REL.

This indicator is lit when the brake is NOT applied.

DC Operators Only:

AC POWER

Indicates AC power is supplying the unit.

DC POWER

Indicates the operator is running on batteries.

BATTERY
CHARGING

Indicates batteries are being charged. Light goes out when batteries reach 90% of full charge.

OPEN GATE

Operator is in open then lockout stage.

POWER
LOCKOUT

Flashes when controls/motor are in lockout mode.