6nxcobranet module, Nxethernet module – Crest Audio CKi Series User Manual

Page 6

Advertising
background image

The NxCobraNet

®

module supports all NexSys control and monitoring functions

as well as delivering two channels of CobraNet digital audio to the amplifier on one eth-
ernet cable. Supported computer controlled NexSys functions include gain, sequential
power, and real time load monitoring.Amplifier monitoring includes input and output level
(VU), DC protect, thermal protect, IGM, clip status, power state, AC mains, heatsink tem-
perature, gain selection, ground lift status, and audio return.

The LED display allows easy in rack readout and monitoring of temperature,

gain, AC voltage, IP address, amplifier ID, as well as CobraNet bundle and channel status.
Individual indicators display fault and mute status by channel as well as ethernet link and
data indicators.

The NxCobraNet module requires no other additions to make it network ready.

The module has an RJ-45 ethernet connection that is made through a Category 5 com-
pliant Neutrik EtherCon connector to ensure a secure connection.

Both the NxCobraNet and the NxEthernet modules can be ordered with CKi

amplifiers or easily installed in the field with two screws and a ribbon cable connection.

The Crest Audio NxEthernet module is designed for clients who need the control of

NexSys but do not need the digital audio delivery that the NxCobraNet module provides.

6

NxCobraNet Module

Optional Module for NexSys Control and CobraNet Digital Audio

NxEtherNet Module

Option Module for NexSys Control of CKi Amplifiers

Advertising