Two-cell battery charger parameters – Cypress CY8C29x66 User Manual

Page 16

Advertising
background image

AN2309

November 25, 2007

Document No. 001-17394 Rev. *B

- 16 -

Two-Cell Battery Charger Parameters

All two-cell battery charger parameters are located in the header file globdefs.h in the project folder. The header file globdefs.h
contains the following parameters:

Table 2. Two-Cell Battery Charger Parameters

Parameter

Unit

Description

Charging Parameters

V

rs

V

Rapid-Charge Stage Start Condition

V

rap

V

Full Charge Voltage (Constant Charge Voltage)

V

crst

V

Recharge Voltage

V

bmax

V

Emergency Shutdown Voltage

V

full_disch

V

Full Discharge Voltage

I

act

A

Activation Stage Charge Current

I

rap

A

Rapid-Charge Stage Current

I

chmax

A

Emergency Shutdown Current

I

rtn

A

Charge Termination Current

Timing Requirements

T

ACT

second

Time Limit for Battery Activation Period

T

RAPID

second

Time Limit for Final Stage of Constant Charge Mode Voltage

T

CHARGE

second

Time Limit for Total Charge Period

T

TERM

second

Minimum Time for Charge Complete (when Ich

≤ Irtn)

Thermistor Measurement Requirements

R

TERM_CH_COLD_STOP

Ohms

Thermistor Resistance for Cold Stop Battery Charge

R

TERM_CH_COLD_RESTART

Ohms

Thermistor Resistance for Cold Restart Battery Charge

R

TERM_CH_HOT_STOP

Ohms

Thermistor Resistance for Hot Stop Battery Charge

R

TERM_CH_HOT_RESTART

Ohms

Thermistor Resistance for Hot Restart Battery Charge

R

TERM_DISCH_COLD_STOP

Ohms

Thermistor Resistance for Cold Stop Battery Discharge

R

TERM_DISCH_HOT_STOP

Ohms

Thermistor Resistance for Hot Stop Battery Discharge

Schematic Parameters

CURRENT_SENSE_R

Ohms

Current-Sense Resistor

TEMPERATURE_R_REF

Ohms

Thermistor Reference Resistor

[+] Feedback

Advertising
This manual is related to the following products: