(NOT TO SCALE)

SECT.

I

PAGE

2

0707

Litho in U.S.A.

17.434"

443mm

21.625"

549mm

23.100"

587mm

25.361"

644mm

2.100"

53mm

24.858"

631mm

1.574"

40mm

30.890"

785mm

1.500"

38mm

RIGHT

SIDE VIEW

FRONT

VIEW

REAR

VIEW

Note: Consult local authorities for venting and installation requirements.

For supply connection use only copper wire suitable for at least 75°C (167°F).

Compartment has capacity for:
Five, 12˝ x 20˝ x 2

1

2

˝ deep Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality standards whether
untreated or pre-treated, based upon 10 hours of use per day,
and a Daily Blowdown, are as follows:

TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY

less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on site water
analysis for recommendations concerning steam generator
feed water treatment (if required), in order to remove or
reduce harmful concentrations of minerals. The use of high-
ly mineralized water will mean that more frequent servicing of
the steam generator will be necessary. The fact that a water
supply is potable is not proof that it will be suitable for the
generator.

NOTES:

Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L/NSF#4 and CSA (AGA, CGA).

H

D

C

C1 C2

ELECTRICAL

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HERTZ

WIRE SIZE (COPPER)*

Standard Wattage

Three Phase - 9 kW Standard

9400

208

3

3

60

26.1

10

9400

240

3

3

60

22.6

10

9400

480

3

3

60

11.4

14

Optional Low Wattage

Three Phase - 6 kW option

6400

208

3

3

60

17.8

12

6400

240

3

3

60

15.4

12

6400

480

3

3

60

7.7

14

*

For supply connection use only copper wire suitable for at least 75˚C. (167˚F).

WATTS

VOLTS

PHASE

WIRES

CYCLE

AMPS

SUPPLY CONNECTION

HERTZ

WIRE SIZE (COPPER)*

Standard Wattage

Single Phase - 9 kW Standard

9400

208

1

2

60

45.2

6

9400

240

1

2

60

39.2

8

Optional Low Wattage

Single Phase - 6 kW option

6400

208

1

2

60

30.8

8

6400

240

1

2

60

26.7

10