1

- Power On Indicator

2

- Electrical Wiring Fault Indicator

3

- AVR Indicator

4

- Using Battery Indicator

5

- Check Battery Indicator

6

- Power Switch

7

- All Outlets Designed for AC Adapters

8

- Two (2) Line Phone/Fax/Modem

Communication Protection Ports

9

- Serial Port to PC

10

- Full-time Surge Protection Outlets

11

- Circuit Breaker

12

- Battery Power Supplied Outlets

CyberPower Systems’ 1250AVR is an ideal unit for high-end computer systems or users who need extended run-times.
The dual 9AH batteries provide ample run-time for today’s power-hungry processors.

The AVR feature ensures that your sensitive electronic equipment receives only clean, consistent, regulated power,
reducing system “lock-ups”. CyberPower backs this unit with an impressive $400,000 connected equipment guarantee.
The 1250AVR sets the standard for quality, reliability and performance at a realistic price.

What is AVR?

Automatic Voltage Regulators increase
low or decrease high voltage to a computer
safe 110/120 volts. The 1250AVR
automatically provides battery backup
power if the line voltage drops below 85
volts or exceeds 150 volts.

High Performance Power Protection with Automatic Voltage Regulation

OfficePower 1250AVR

Automatic Voltage Regulator

Part Number

CPS1250AVR

Sell Unit Dims. (L" x W" x H")

15.87” x 9.25” x 9.12”

Sell Unit Net Weight

30 LBS.

Master Carton Quantity

2 UNITS

Master Dims. (L" x W" x H")

19.25” x 16.875” x 9.75”

Master Weight

60 LBS.

UPC Number

6 49532 01250 3

PACKAGING SPECIFICATIONS

Model

CPS1250AVR

VA Rating

1250VA

Watts

670W

Input Voltage on Utility

85V to150V

Frequency on Utility

57Hz to 63 Hz

Output Voltage on Battery

120V +/- 5%

Frequency on Battery

60Hz

Surge Energy Capacity

1500 Joules

Maximum Surge Current

36,000 Amps

Overload Protection

Internal circuitry limiting. On-line circuit breaker

Battery Run-time

40 to 100 mins.

Typical Battery Recharge Time

8 hours

Total number of receptacles

3 battery / surge, 3 full-time surge-only

Visual Indicators

Power On/Off, Automatic Voltage Regulator, Using Battery, Site Wiring Fault

Audible Indicators

Battery on, Low battery, UPS overload

Warranty

Three Year Limited Warranty on UPS unit and battery

Conformance Approvals

UL 1778, cUL, FCC Doc Class B

Included Software

PowerPanelPlusTM Power Management Software

Connected Equip. Guarantee

$400,000

TECHNICAL SPECIFICATIONS