Dell PowerVault DR6000 User Manual

Page 118

Advertising
background image

Error Code

Message Information

Action

Check the event log for power supply failures. Review
system configuration and power consumption.

PWR1004

Message

The system performance degraded because power capacity
has changed.

Details

The system may power down or operate in a performance
degraded state.

Action

Check the event log for power supply failures. Review
system configuration and power consumption and upgrade
or install power supplies accordingly.

PWR1005

Message

The system performance degraded because the user-
defined power capacity has changed.

Details

The user-defined power settings have affected system
operation.

Action

If unintended, review system configuration changes and
power policy.

PWR1006

Message

The system halted because system power exceeds capacity.

Details

The system halted because system power exceeds capacity.

Action

Review system configuration, upgrade power supplies or
reduce system power consumption.

RFM1008

Message

Failure detected on Removable Flash Media <name>.

Details

An error was reported during a SD card read or write.

Action

Reseat the flash media. If the problem persists, see

Getting

Help

.

RFM1014

Message

Removable Flash Media <name> is write protected.

Details

The card is write-protected by the physical latch on the SD
card. A write-protected card cannot be used.

Action

If unintended, remove the media and disable write
protection.

RFM1201

Message

Internal Dual SD Module redundancy is lost.

Details

Either one or both the SD cards are not functioning properly.

Action

See

Getting Help

.

118