Switching characteristics, Switching waveforms – Cypress CY62138EV30 User Manual

Page 5

Advertising
background image

CY62138EV30

MoBL

®

Document #: 38-05577 Rev. *A

Page 5 of 9

Switching Characteristics

(Over the Operating Range)

[9]

Parameter

Description

45 ns

Unit

Min.

Max.

Read Cycle

t

RC

Read Cycle Time

45

ns

t

AA

Address to Data Valid

45

ns

t

OHA

Data Hold from Address Change

10

ns

t

ACE

CE LOW to Data Valid

45

ns

t

DOE

OE LOW to Data Valid

22

ns

t

LZOE

OE LOW to Low Z

[10]

5

ns

t

HZOE

OE HIGH to High Z

[10,11]

18

ns

t

LZCE

CE LOW to Low Z

[10]

10

ns

t

HZCE

CE HIGH to High Z

[10, 11]

18

ns

t

PU

CE LOW to Power-up

0

ns

t

PD

CE HIGH to Power-up

45

ns

Write Cycle

[12]

t

WC

Write Cycle Time

45

ns

t

SCE

CE LOW to Write End

35

ns

t

AW

Address Set-up to Write End

35

ns

t

HA

Address Hold from Write End

0

ns

t

SA

Address Set-up to Write Start

0

ns

t

PWE

WE Pulse Width

35

ns

t

SD

Data Set-up to Write End

25

ns

t

HD

Data Hold from Write End

0

ns

t

HZWE

WE LOW to High Z

[10, 11]

18

ns

t

LZWE

WE HIGH to Low Z

[10]

10

ns

Switching Waveforms

Read Cycle No. 1 (Address Transition Controlled)

[13, 14]

Notes:

9. Test Conditions for all parameters other than three-state parameters assume signal transition time of 3 ns or less (1 V/ns), timing reference levels of V

CC(typ)

/2,

input pulse levels of 0 to V

CC(typ)

, and output loading of the specified I

OL

/I

OH

as shown in the “AC Test Loads and Waveforms” section.

10. At any given temperature and voltage condition, t

HZCE

is less than t

LZCE

, t

HZOE

is less than t

LZOE

, and t

HZWE

is less than t

LZWE

for any given device.

11. t

HZOE

, t

HZCE

, and t

HZWE

transitions are measured when the output enter a high-impedance state.

12. The internal write time of the memory is defined by the overlap of WE, CE = V

IL

. All signals must be ACTIVE to initiate a write and any of these signals can

terminate a write by going INACTIVE. The data input set-up and hold timing should be referenced to the edge of the signal that terminates the write.

13. Device is continuously selected. OE, CE = V

IL

.

14. WE is HIGH for read cycle.

ADDRESS

DATA OUT

PREVIOUS DATA VALID

DATA VALID

t

RC

t

AA

t

OHA

[+] Feedback

Advertising