Dell PowerEdge 1650 User Manual

Page 18

Advertising
background image

system board - please run SETUP program

Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.

the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See

Figure A

-2

for jumper location.

Replace the battery. See "

Replacing the System Battery

" in

"Installing System Board Options."

CPUs with different cache sizes detected

Two different types of microprocessors
are installed.

Install a correct version of the microprocessor so that both
microprocessors have the same level 2 cache size. See
"

Adding or Replacing a Microprocessor

" in "Installing

System Board Options."

Decreasing available memory

One or more memory modules improperly
seated or faulty.

Remove and reseat the memory modules. See "

Removing

Memory Modules

" in "Installing System Board Options." If

the problem persists, replace the memory modules. If the
problem persists, see "

Getting Help

."

Diskette drive 0 seek failure

Faulty or improperly inserted diskette,
incorrect configuration settings in System
Setup program, loose diskette interface
cable.

Replace the diskette. Run the System Setup program to
correct the diskette drive type. See "Using the System
Setup Program" in the User's Guide. Check that the
diskette drive interface cable is connected correctly. See
"

Installing Drives

."

Diskette read failure

Faulty diskette, or faulty or improperly
connected diskette drive.

Check that the diskette drive interface cable is connected
correctly. See "

Installing Drives

."

Diskette subsystem reset failed

Faulty diskette/CD drive controller
(defective system board).

Replace the system board. See "

Getting Help

."

ECC memory error

Improperly seated or faulty memory
modules.

Remove and reseat the memory modules. See "

Removing

Memory Modules

" in "Installing System Board Options." If

the problem persists, replace the memory modules. If the
problem persists, see "

Getting Help

."

Embedded server management error

Embedded server management is not present

Embedded server management memory
may be temporarily corrupted.

To clear the embedded server management memory, shut
down the system, disconnect the power cord(s), wait
approximately 30 seconds, and then reconnect the power
cord(s) and restart the system. If the problem persists,
see "

Getting Help

."

Error: Dell Remote Access Card initialization

failure

Defective server management card or
system board.

Replace the expansion card. See "

Installing Expansion

Cards

" in "Installing System Board Options." If the problem

persists, replace the system board. See "

Getting Help

."

Gate A20 failure

Faulty keyboard controller (defective
system board).

Replace the system board. See "

Getting Help

."

Hard disk controller failure

Hard disk read failure

Incorrect configuration settings in System
Setup program, improperly connected
hard drive, faulty hard-drive controller
subsystem (defective system board), or
loose power cable.

Check the hard-drive configuration settings in the System
Setup program. See "Using the System Setup Program" in
the User's Guide. Reinstall the hard drive. See "

Installing

Drives

." Check the interface cable and power cable

connections to the backplane board. See "

Installing

Drives

."

Invalid configuration information - please run

SETUP program

Incorrect configuration settings in System
Setup program, NVRAM_CLR jumper is
installed, or faulty system battery.

Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide. Remove
the NVRAM_CLR jumper. See

Figure A

-2

for jumper location.

Replace the battery. See "

Replacing the System Battery

" in

"Installing System Board Options."

Invalid memory configuration detected.

Potential for data corruption exists!

Memory modules are not installed in
matched pairs.

Install memory modules in matched pairs. See "

Installing

Memory

" in "Installing System Board Options."

Invalid NVRAM configuration, resource re-

allocated

System configuration data has been
ignored.

Check the System Setup configuration settings. See "Using
the System Setup Program" in the User's Guide.

I/O parity interrupt at address

Expansion card(s) is improperly installed
or faulty.

Reinstall the expansion card(s). See "

Installing Expansion

Cards

" in "Installing System Board Options." If the problem

persists, replace the expansion card(s).

Keyboard controller failure

Defective keyboard/mouse controller
(defective system board).

Replace the system board. See "

Getting Help

."

Keyboard data line failure

Keyboard stuck key failure

Keyboard clock line failure

Keyboard failure

Keyboard cable connector is loose or
improperly connected; defective
keyboard; defective keyboard/mouse
controller (defective system board).

Check the keyboard cable connection. Replace the
keyboard. If the problem persists, replace the system
board. See "

Getting Help

."

Memory address line failure at address, read

value expecting value

Memory high data line failure at start address

to end address

Memory high address line failure at start

address to end address

Memory double word logic failure at start

address to end address

Memory odd/even logic failure at start address

to end address

Memory write/read failure at address, read

value expecting value

Faulty or improperly seated memory
modules or defective system board.

Remove and reseat the memory modules. See "

Installing

Memory Modules

" in "Installing System Board Options." If

the problem persists, replace the memory modules. If the
problem persists, see "

Getting Help

."

Memory parity failure at start address to end

address

Improperly seated or faulty memory
modules.

Remove and reseat the memory modules. See "

Installing

Memory Modules

" in "Installing System Board Options." If

the problem persists, replace the memory modules. If the

Advertising