Dell PowerEdge FX2/FX2s User Manual

Page 8

Advertising
background image

8

|

ww

w.del

l.com

|

support.dell

.com

Dell Networking OS version 9.6(0.0) requires FN I/O Aggregator Boot Flash image version 4.0.1.3 and Boot Selector image
version 4.0.0.2. If any higher versions of Boot Flash or Boot Selector versions are present in the unit, do not upgrade the Boot
Flash and Boot Selector images respectively.
The Boot Flash and Boot Selector images can be upgraded at the same time by specifying

all in the command. These can be

upgraded separately by selecting bootflash-image or bootselector-image respectively.
The Boot Flash and Boot Selector images can be upgraded for individual stack units by specifying the particular stack unit ID
from the range [0-5] in the command. These can be upgraded to all the stack units together by selecting all option instead of
the stack unit ID.
The Boot Flash and Boot Selector images can be saved in two partitions A: and B: and the user can select the partition to be
upgraded by specifying A: or B: in the command.

Dell# upgrade boot all stack-unit all ftp: A:

Address or name of remote host []: 10.16.127.35

Destination file name []: FTOS-XL-9.6.0.0.bin

User name to login remote host: ftpuser

Password to login remote host:

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Current Boot information in the system:

============================================

Card BootFlash Current Version New Version

---------------------------------------------------------------------------------------------

Unit0 Boot Flash 4.0.1.1 4.0.1.3

Unit1 Boot Flash 4.0.1.1 4.0.1.3

*************************************************************************

* Warning - Upgrading boot flash is inherently risky and should only*

* be attempted when necessary. A failure at this upgrade may cause*

* a board RMA. Proceed with caution !*

*************************************************************************

Proceed Boot Flash image for all units [yes/no]: yes

!!!!!!!!!!!!!!!!

Erasing IOM Primary Bootflash Image, please wait

.!.!.!.!.!.!.!..!.......................

Bootflash image upgrade for all completed successfully.

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Current Boot information in the system:

============================================

Card BootSelector Current Version New Version

---------------------------------------------------------------------------------

Unit0 Boot Selector 4.0.0.1 4.0.0.2

Unit1 Boot Selector 4.0.0.1 4.0.0.2

*************************************************************************

* Warning - Upgrading boot selectors is inherently risky and should *

* only be attempted when necessary. A failure at this upgrade may*

* cause a board RMA. Proceed with caution ! *

*************************************************************************

Proceed Boot Selector image for all units [yes/no]: yes

!!!

Erasing IOM Boot Selector Image, please wait

.!!.!..!.!..!.!.......

Bootselector image upgrade for all completed successfully.

Dell#

6.

Change the Primary Boot Parameter of the
FN I/O Aggregator to the upgraded
partition A: or B:

boot system stack-unit [0-5 | all] primary
[system A: | system B: | tftp://<URL>]

CONFIGURATION

7.

Save the configuration so that the
configuration will be retained after a reload
using

write memory command.

write [memory]
In case of a stack setup, the configuration will be saved
in the Management as well as the standby units.

EXEC Privilege

Dell# write memory

!

Synchronizing data to peer Stack-unit

!!!!!!!!

Dell#