Switching characteristics – Cypress CY7C1422BV18 User Manual

Page 24

Advertising
background image

CY7C1422BV18, CY7C1429BV18
CY7C1423BV18, CY7C1424BV18

Document #: 001-07035 Rev. *D

Page 24 of 30

Output Times

t

CO

t

CHQV

C/C Clock Rise (or K/K in single
clock mode) to Data Valid

0.45

0.45

0.45

0.45

0.50

ns

t

DOH

t

CHQX

Data Output Hold after Output C/C
Clock Rise (Active to Active)

–0.45

–0.45

–0.45

–0.45

–0.50

ns

t

CCQO

t

CHCQV

C/C Clock Rise to Echo Clock Valid

0.45

0.45

0.45

0.45

0.50

ns

t

CQOH

t

CHCQX

Echo Clock Hold after C/C Clock
Rise

–0.45

–0.45

–0.45

–0.45

–0.50

ns

t

CQD

t

CQHQV

Echo Clock High to Data Valid

0.27

0.27

0.30

0.35

0.40

ns

t

CQDOH

t

CQHQX

Echo Clock High to Data Invalid

–0.27

–0.27

–0.30

–0.35

–0.40

ns

t

CQH

t

CQHCQL

Output Clock (CQ/CQ) HIGH

[24]

1.24

1.35

1.55

1.95

2.45

ns

t

CQHCQH

t

CQHCQH

CQ Clock Rise to CQ Clock Rise
(rising edge to rising edge)

[24]

1.24

1.35

1.55

1.95

2.45

ns

t

CHZ

t

CHQZ

Clock (C/C) Rise to High-Z
(Active to High-Z)

[25, 26]

0.45

0.45

0.45

0.45

0.50

ns

t

CLZ

t

CHQX1

Clock (C/C) Rise to Low-Z

[25, 26]

–0.45

–0.45

–0.45

–0.45

–0.50

ns

DLL Timing

t

KC Var

t

KC Var

Clock Phase Jitter

0.20

0.20

0.20

0.20

0.20

ns

t

KC lock

t

KC lock

DLL Lock Time (K, C)

1024

1024

1024

1024

1024

Cycles

t

KC Reset

t

KC Reset

K Static to DLL Reset

30

30

30

30

30

ns

Switching Characteristics

(continued)

Over the Operating Range

[20, 21]

Cypress

Parameter

Consortium

Parameter

Description

300 MHz

278 MHz

250 MHz

200 MHz

167 MHz

Unit

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

Notes

24. These parameters are extrapolated from the input timing parameters (t

KHKH

- 250 ps, where 250 ps is the internal jitter. An input jitter of 200 ps (t

KC Var

) is already

included in the t

KHKH

). These parameters are only guaranteed by design and are not tested in production.

25. t

CHZ

, t

CLZ

, are specified with a load capacitance of 5 pF as in (b) of

AC Test Loads and Waveforms

. Transition is measured ± 100 mV from steady-state voltage.

26. At any voltage and temperature t

CHZ

is less than t

CLZ

and t

CHZ

less than t

CO

.

[+] Feedback

Advertising