PV22xS consists of four digital temperature probes, which in conjunction with
SES processor provides device protection against adverse thermal conditions.
PV22xS is designed to operate at ambient temperature of 10

O

C to 35

O

C. Once

the temperature probe detects ambient temperature to be below 0

O

C or above

50

O

C, SES processor notifies host of critical temperature range, which would then

initiate a thermal shut down process. In case, PV22xS temperature probes detect
ambient temperature either to be at or below -5

O

C or above 55

O

C, SES processor

initiates a self shutdown process and hence protecting the device against adverse
thermal conditions.

Serviceability Capabilities

• All components including backplane easily accessible and replaceable in rack

• LED indicators for visual status reporting on internal components

• Audible alarm to notify critical/non-critical status (for details please refer to

PV22xS user’s guide). Status is also reported to system management tools –
OpenManage – OMSM or Array manager (for details refer to OpenManage user’s
guide)