Dell PowerVault NX3500 User Manual

Racking your solution 2, Cabling your solution, Turning on your solution

Advertising
background image

Setting Up Your PowerVault Network Attached Storage Solution

WARNING: Before you set up and operate your Dell PowerVault system, review

the safety instructions that shipped with your system.

Read the Dell Software License Agreement

Before using your system, please read the Dell Software License Agreement that

came with the system.
If you do not accept the terms of the agreement, please call the customer

assistance telephone number. For customers in the United States,

call 800-WWW-DELL (800-999-3355). For customers outside the United States,

visit support.dell.com and select your country or region from the top of the page.

Verifying Package Contents

Verify that all components listed on your packing slip are available. Save all
documentation and accessories.

Locating Your System Service Tag

Your system is identified by a unique Express Service Code and Service Tag number.

The Express Service Code and Service Tag are found on the front of the system by

pulling out the information tag.
This information is used by Dell to route support calls to the appropriate personnel.

Installing the Solution in a Rack

The solution requires a properly grounded electrical outlet, a compatible rack,

and a rack installation kit.
For information about installing the rails for the PowerVault NX3500 system,

see the

Rack Installation Instructions

that shipped with your rail kit.

For information about installing rails for the backup power supply,

see the

Dell PowerVault NX3500 Getting Started Guide.

Installation Guidelines

The PowerVault NX3500 hardware configuration consists of two PowerVault

NX3500 controller units and one backup power supply (BPS) unit. The BPS

is required even if you have an uninterruptible power supply system in your

environment. Install the three hardware components adjacent to one another in

the same rack.
Depending on your configuration, use 18 or 22 Category 5E or Category 6 Ethernet

cables with RJ45 connectors. Connect 14 cables to the PowerVault NX3500

controllers and four or eight cables to the MD storage array.
It is recommended that you use a minimum of four network switches as shown in

step 2.

Connecting the Battery in the Backup Power Supply

CAUTION: Always verify the voltage rating of the backup power supply.

Connecting a 230 VAC into a 120 V back up power supply damages the backup
power supply.

Remove the power module front cover.

1.

Remove the battery from the power module.

2.

Rotate the battery 180 degrees.

3.

Reinstall the battery in the power module.

4.

Repeat step 2 to step 4 of this procedure for the second battery.

5.

Attach the power module front cover.

6.

1

|

Racking Your Solution

2

|

Cabling Your Solution

Verify that your network environment and modular disk storage arrays are turned on.
Turn on the components in the following order:

Dell backup power supply

1.

Dell PowerVault NX3500 controllers

2.

Planning

Proper planning is essential to successfully deploy the PowerVault NX3500 solution. This placemat contains one scenario using two redundant iSCSI switches. If your SAN is configured in a different configuration, see the

Administrator’s Guide

for additional cabling options.

It is recommended that you complete the IP chart in step 4 prior to deploying the solution. The IP chart is also available in the

Administrator’s Guide

. It is also recommended that you set your switch MTU size to 9000 or greater and enable Spanning Tree Portfast and flow control.

3

|

Turning On Your Solution

Network Cabling

SAN switches

Client switches

PowerVault NX3500 contoller 0

PowerVault NX3500 contoller 1

PowerVault MD storage array

Client connections
Internal network and SAN connections
Peer connections

Power Cabling

PowerVault NX3500 controller 0
PowerVault NX3500 controller 1
To the grid

PowerVault NX3500 controller 0

To power source 1

To power source 2

PowerVault NX3500 controller 1

Backup power supply

To power source 1

To power source 2

USB

Power

USB

Power

Cabling Worksheet

Peer

connection

0

Peer

connection

1

SAN

connection

B

SAN

connection

A

Client

connection

1

Client

connection

2

Internal connection

to SAN switch

PowerVault NX3500 Controller 0 Controller 1

Client connection 1

To client switch

To client switch

Client connection 2

To client switch

To client switch

Peer connection 0

Back to back (peer connection 0 to peer

connection 0)

Back to back (peer connection 0 to peer con-

nection 0)

Peer connection 1

Back to back (peer connection 1 to peer

connection 1)

Back to back (peer connection 1 to peer con-

nection 1)

SAN connection A

To SAN switch (A)

To SAN switch (B)

SAN connection B

To SAN switch (B)

To SAN switch (A)

Internal connection

To SAN switch (B)

To SAN switch (A)

PowerVault MD Storage Array Connection

Port 0

To SAN switch (A)

Port 1

To SAN switch (B)

Advertising