Post error codes, Collecting system event log for investigation – Dell PowerEdge C6100 User Manual

Page 23

Advertising
background image

About Your System

23

POST Error Codes

Collecting System Event Log for Investigation

Error Messages are logged in the System Event Log (SEL). The SEL can be
accessed through system BIOS and the BMC setup for investigation. You can
also access SEL by browsing to the IP address of the BMC.

Code

Log in BMC Cause

Corrective Actions

0000h

Yes

Timer Count Read/Write Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

0003h

Yes

CMOS Battery Error

See "Troubleshooting the
System Battery" on
page 118.

0004h Yes

CMOS Diagnostic Status Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

0005h

Yes

CMOS Checksum Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

000Bh

Yes

CMOS Memory Size Error

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists, see
"Getting Help" on page 143.

book.book Page 23 Thursday, March 4, 2010 4:38 PM