Wiring installation (cont’d) – Chromalox HEATFLO KDS-3 User Manual

Page 3

Advertising
background image

L1

L2

L3

AL1

AL2

AL3

Power
Disconnect
Switch

Contactor

To
Power
Supply

See
Note 2

See Notes

Pigtail
Leads

L1

L2

L3

AL1

AL2

AL3

Power
Disconnect
Switch

Contactor (1)

To
Power
Supply

Contactor (2)

Figure 10

KUH-02 through KUH-25

Power Disconnect Switch

Figure 11

Notes:
1.
This illustration shows wiring hook up for three phase

service. Remove lead wires marked L2 and AL2 when
using one phase power service.

2. For units without contactors, disconnect switch is to

be wired to lead wires on heater power.

3. Use copper supply wire only with this switch.

KUH-30 through KUH-45 units with 2 contactors
where the total load does not exceed 48 Amps.

WIRING

INSTALLATION (Cont’d)

POWER DISCONNECT SWITCH (Available as a kit or

factory installed option.) (KDS-1)This switch disconnects the
power to power leads when the handle is rotated to the “0” posi-
tion (left). The power is on when the switch handle is rotated to
the “1” position (top) position. (KDS-2 and KDS-3) This switch
disconnects power to the power leads when the handle is placed
in its full lower position. The power is on when the switch handle
is in its full upper position.

1. Use the three pigtail leads supplied with kit (40 & 80 Amp) when

connecting to the power line.
a. Use No. 4GA Copper conductor wire only for 100 Amp dis-

connect when wiring to the power line.

2. The power disconnect wiring to the heater is to be made using the

pigtail leads supplied on the heaters up to and including 25 kW.
On larger heaters, the installer should supply 105˚C type AWM
600V wire.

ELECTRIC SHOCK HAZARD. Disconnect all power
before installing disconnect switch. Failure to do
so could result in personal injury or property dam-
age. Disconnect switch must be installed by a
qualified person and must be effectively grounded
in accordance with the National Electrical Code,
NFPA 70.

For future replacement parts, the model number should be modi-
fied on the nameplate to show that a disconnect kit has been field
installed on the heater. A label kit (see Figure 14) (P/N 170-
302788-002) has been included in the plastic envelope located in
the disconnect kit. Cut off the appropriate number for the size dis-
connect being installed (40 Amp = 1; 80 Amp = 2; 100 Amp = 3).
The label has a pressure sensitive adhesive back so that the num-
ber can be placed over the “0” as shown in Figure 14.

KDS–2 and KDS – 3

8. The cover plate should be placed over the rectangular opening

with its four mounting holes lined up with the four holes in the
cabinet and the four holes in the mounting bracket (see Figure 7).

9. Insert the four self tapping screws into the four holes until they

engage the holes in the mounting bracket and tighten until they
are secure (see Figure 8).

10. Place plastic bezel over the installed switch and push towards the

switch until the tabs snap into place (see Figure 9).

Rear Case

Cover Plate

(4) 8-32 Screws

Mount Switch Assembly
Onto Rear Case of Heater

Figure 7

Figure 8

Figure 9

Rear Case

Switch Assembly Mounted to Rear Case

Rear Case

Snap Plastic Housing
Into Place

3