Dell PowerEdge T110 II User Manual

Page 26

Advertising
background image

26

About Your System

Plug & Play

Configuration

Error.

Error encountered in

initializing PCIe device;

faulty system board.

Install the NVRAM_CLR

jumper in the clear position

(pins 1 and 3) and reboot the

system. See Figure 6-1 for

jumper location. If the

problem persists, see

"Troubleshooting Expansion

Cards" on page 124.

Quad rank DIMM

detected after

single rank or

dual rank DIMM in

socket.

Invalid memory

configuration.

Ensure that the memory

modules are installed in a valid

configuration. See "General

Memory Module Installation

Guidelines" on page 86.

Read fault.

Requested sector

not found.

The operating system

cannot read from the hard

drive, optical drive, or USB

device; the system could

not find a particular sector

on the disk, or the

requested sector is

defective.

Replace the optical medium,

USB medium or device.

Ensure that the USB or SATA

cables are properly connected.

See "Troubleshooting a USB

Device" on page 112,

"Troubleshooting an Optical

Drive" on page 121, and

"Troubleshooting a Hard

Drive" on page 123 for the

appropriate drive(s) installed

in your system.

SATA Port x

device not found.

There is no device

connected to the specified

SATA port.

Information only.

SATA port x

device auto-

sensing error.

SATA port x

device

configuration

error.

SATA port x

device error.

The drive connected to the

specified SATA port is

faulty.

Replace the faulty drive.

Message

Causes

Corrective Actions

Coaster_HOM.book Page 26 Monday, November 3, 2014 3:23 PM

Advertising