Go to step 12 if an error message appear, Indicated, go to step 12 – Dell PowerEdge R310 User Manual

Page 154

Advertising
background image

154

Troubleshooting Your System

9 Close the system. See "Closing the System" on page 79.

10 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals.

11 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 57.
If the problem is not resolved, proceed with the next step.

12 Turn off the system and attached peripherals, and disconnect the system

from the power source.

13 Open the system. See "Opening the System" on page 78.
14 If a diagnostic test or error message indicates a specific memory module as

faulty, swap or replace the module.

15 To troubleshoot an unspecified faulty memory module, replace the

memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 109.

16 Close the system. See "Closing the System" on page 79.
17 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals.

18 As the system boots, observe any error message that appears and the

diagnostic indicators on the front of the system.

19 If the memory problem is still indicated, repeat step 12 through step 18 for

each memory module installed.
If the problem persists after all memory modules have been checked,
see "Getting Help" on page 169.

R310HOM.book Page 154 Thursday, March 4, 2010 1:03 AM