Table 1-63. Threshold Settings and Converting Formulas

(continued)

Sensor
Number

Sensor Name The Converting Formula

Upper non-
recoverable

Upper
critical

Upper
non-
critical

Lower non-
recoverable

Lower
critical

Lower
non-
critical

Temperature
41h

CPU1 Temp

Actual_Reading (degrees C) = Raw_Data
5A

50

46

20

25

29

42h

CPU2 Temp Actual_Reading (degrees C) = Raw_Data

5A

50

46

20

25

29

43h

DIMM ZONE

1 Temp

Actual_Reading (degrees C) = Raw_Data
3C

32

28

17

1A

1E

44h

DIMM ZONE

2 Temp

Actual_Reading (degrees C) = Raw_Data
3C

32

28

17

1A

1E

45h

PCH Temp

Actual_Reading (degrees C) = Raw_Data
5A

50

46

17

1A

1E