Full height blade io to iom mapping – Dell POWEREDGE M1000E User Manual

Page 15

Advertising
background image

Quadport Capable Hardware for the M1000e Modular Chassis

Page 13

Full Height Blade IO to IOM mapping

Mapping for quadport capable components in full height blades uses the following formulas:

(“N” being the slot the blade is installed into; 1-8. P = The internal Port Number)

“Mezz1-FAB_C”, port one and two: “P = N” (Internal Port number = Blade Slot number)

“Mezz1-FAB_C”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16)

“Mezz2-Fab_B”, port one and two: “P = N” (Internal Port number = Blade Slot number)

“Mezz2-Fab_B”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16)

“Mezz3-FAB_C”, port one and two: “P + 8” (Internal Port number = Blade Slot number + 8)

“Mezz3-FAB_C”, port three and four: “P = N+24” (Internal port number = Blade slot number + 24)

“Mezz4-Fab_B”, port one and two: “P + 8” (Internal Port number = Blade Slot number + 8)

“Mezz4-Fab_B”, port three and four: “P = N+24” (Internal port number = Blade slot number + 24)

Example:

Full height blade installed in chassis slot 1, 2 Quadport capable Mezzanine cards in “Mezz2-Fab_B” and
“Mezz4-Fab_B”.

• “Mezz2-Fab_B” port 1 Maps to IOM B1, port 1
• “Mezz2-Fab_B” port 2 Maps to IOM B2, port 1
• “Mezz2-Fab_B” port 3 Maps to IOM B1 port 17
• “Mezz2-Fab_B” port 4 Maps to IOM B2 port 17
• “Mezz4-Fab_B” port 1 Maps to IOM B1, port 9
• “Mezz4-Fab_B” port 2 Maps to IOM B2, port 9
• “Mezz4-Fab_B” port 3 Maps to IOM B1 port 25
• “Mezz4-Fab_B” port 4 Maps to IOM B2 port 25

Advertising