Quadport Capable Hardware for the M1000e Modular Chassis
Page 13
Full Height Blade IO to IOM mapping
Mapping for quadport capable components in full height blades uses the following formulas:
(“N” being the slot the blade is installed into; 1-8. P = The internal Port Number)
“Mezz1-FAB_C”, port one and two: “P = N” (Internal Port number = Blade Slot number)
“Mezz1-FAB_C”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16)
“Mezz2-Fab_B”, port one and two: “P = N” (Internal Port number = Blade Slot number)
“Mezz2-Fab_B”, port three and four: “P = N+16” (Internal port number = Blade slot number + 16)
“Mezz3-FAB_C”, port one and two: “P + 8” (Internal Port number = Blade Slot number + 8)
“Mezz3-FAB_C”, port three and four: “P = N+24” (Internal port number = Blade slot number + 24)
“Mezz4-Fab_B”, port one and two: “P + 8” (Internal Port number = Blade Slot number + 8)
“Mezz4-Fab_B”, port three and four: “P = N+24” (Internal port number = Blade slot number + 24)
Example:
Full height blade installed in chassis slot 1, 2 Quadport capable Mezzanine cards in “Mezz2-Fab_B” and
“Mezz4-Fab_B”.
• “Mezz2-Fab_B” port 1 Maps to IOM B1, port 1
• “Mezz2-Fab_B” port 2 Maps to IOM B2, port 1
• “Mezz2-Fab_B” port 3 Maps to IOM B1 port 17
• “Mezz2-Fab_B” port 4 Maps to IOM B2 port 17
• “Mezz4-Fab_B” port 1 Maps to IOM B1, port 9
• “Mezz4-Fab_B” port 2 Maps to IOM B2, port 9
• “Mezz4-Fab_B” port 3 Maps to IOM B1 port 25
• “Mezz4-Fab_B” port 4 Maps to IOM B2 port 25