Configuring ingress Port Mirroring

13

Configuring ingress Port Mirroring

To configure Port Mirroring for incoming packets only, perform the following steps in global
configuration mode.

1. Open a monitor session and assign a session number

switch(config)# monitor session 1

2. Configure the source port and the destination port, with the rx parameter for received packets.

The destination port is always an external port.

switch(config-mon-sess-1)#source intengigabitethernet 0/1 destination

extengigabitethernet 0/18 direction rx

3. Optional: Use the description command to add a label to the monitor session.

switch(config-mon-sess-1)#description Hello World!

4. Repeat

step 1

and

step 2

as needed for additional ports.

A monitor session can have only one port. For additional ports you must create additional
monitor sessions

Configuring egress Port Mirroring

To configure Port Mirroring for incoming packets only, perform the following steps in global
configuration mode.

1. Open a monitor session and assign a session number

switch(config)# monitor session 1

2. Configure the source port and the destination port, with the tx parameter for transmitted

packets.

The destination port is always an external port.

switch(config-mon-sess-1)#source intengigabitethernet 0/1 destination

extengigabitethernet 0/18 direction tx

3. Optional: Use the description command to add a label to the monitor session.

switch(config-mon-sess-1)#description Hello World!

4. Repeat

step 1

and

step 2

as needed for additional ports.

A monitor session can have only one port. For additional ports you must create additional
monitor sessions

Configuring bidirectional Port Mirroring

To configure Port Mirroring for packets traveling in both directions, perform the following steps in
global configuration mode.

1. Open a monitor session and assign a session number

switch(config)# monitor session 1