Troubleshooting Guide

Error: -5004.

Error occurred

while

attempting to

create OS

volume.

Drives in the expected

system slots dedicated

for the operating system

are empty.

To workaround this issue, perform

one of the following steps:

• Ensure that all drives in the

operating system drive slots are

correctly attached and do not

have data on them. Physical disks

for the operating system must be

of the same type and must meet

the minimum size requirements.

• Enter the PERC BIOS during the

operating system boot operation

and ensure that there are no

foreign configurations, drives are

clean of all data, the drives meet

the minimum size requirement,

and are fully functioning and

accessible. For more information,

see the PERC documentation at

support.dell.com/manuals.

Error: -5005.

Error occurred

while

attempting to

create OS

volume.

Drives in expected

operating system slots

have existing foreign

configurations.

To workaround this issue, enter the

PERC BIOS during the operating

system boot operation and ensure

that there are no foreign

configurations, drives are clean of

all data, the drives meet the

minimum size requirement, and

are fully functioning and

accessible. For more information,

see the PERC documentation at

support.dell.com/manuals.

Table 1. Installation Issues

(continued)

Issue

Description

Workaround / Solution