Known issues – Dell POWEREDGE M1000E User Manual

Page 4

Advertising
background image

Known Issues

Issue 1:

Description
XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device Page and
OS.
Resolution
Virtual reseat or Physical reseat of the server.
Versions/Systems Affected
All CMC versions including CMC 5.0 and PowerEdge servers with iDRAC7 or earlier.

Issue 2:

Description
Io-Identity values are displayed partially in the cmc getmacaddress -c all for 8F6NV(Intel).
Resolution
None
Versions/Systems Affected
CMC 5.0 and servers with Intel adapetrs Intel(R) 10G 2P X520-k bNDC and Intel 10GbE/FCoE Dual KR X-
520.

Issue 3:

Description
RACADM displays non ISCI MAC addresses after using ISCI filter in “getmacaddress –m server-x –t iscsi”
command.
Resolution
None
Versions/Systems Affected
All CMC versions including CMC 5.0.

Issue 4:

Description
VLAN settings from the leader chassis are not propagating to member chassis.

Resolution
Login to each member chassis CMC GUI and set the VLAN for iDRAC (Server Overview -> Setup ->
VLAN page).
Versions/Systems Affected
All CMC versions including CMC 5.0 and PowerEdge servers with iDRAC7 or earlier.

Advertising