Dell PowerVault NX1950 User Manual

Page 37

Advertising
background image

Detailed End-to-End iSCSI Setup

37

To configure the iSCSI HA instance perform the following steps in all

nodes of cluster system:

NOTE:

To perform this procedure, you must have Administrator rights on

the local computer. For best practices, use the Run option to perform this

procedure.

a

Open the PowerVault NX1950 Management Console, right-click

Microsoft iSCSI Software Target, and then click Create HA Instance

for iSCSI.

b

In the Create Highly Available Instance for iSCSI Storage dialog box,

click

Add.

c

In the Add IP Address Resource section, choose the following options:

Resource name—Retain the default value or enter a different

name

IP address—IP address to be used by iSCSI initiators to connect

to the iSCSI Target

Subnet mask—subnet mask to be used by iSCSI initiators to

connect to the iSCSI Target

Network interface—select the name of the network interface to

be used for the IP address resource of the cluster resource group.

d

Click OK and add IP address for the second NIC if you have

redundant iSCSI NIC. Click

OK again.

NOTE:

Before you create iSCSI Virtual Disks, create few Dell|EMC LUNs or

PowerVault MD3000 LUNs and assign them to the Cluster's highly-available

Sever (iSCSI HA instance) using PowerVault NX1950 Management console.

If you prefer to use the existing volume of Cluster, then move the volume to

iSCSI HA instances using Cluster Administrator. From any PowerVault NX1950

cluster node, go to Start→ All programs→ Administrative Tools→ Cluster

Administrator.