Operating Procedures

Daily Shut-Down Procedures

1. Set the Auto-On/Off lever to the Off position.

2. Unplug the power cord from the receptacle.

3. Set the outlet pressure to zero on the regulator.

4. Remove any air tools or accessories. When draining

the tank, always use ear and eye protection. Drain the

tank in a suitable location; condensation will be present

in most cases of draining.

5. Open the drain valve allowing air to bleed from the

tank. After all of the air has bled from the tank, close

the drain valve to prevent debris buildup in the valve.

When draining the tank, always use ear and eye protection.

Drain the tank in a suitable location; condensation will be

present in most cases of draining.

Water that remains in the tank during storage will corrode

and weaken the air tank which could cause the tank to

rupture. To avoid serious injury, be sure to drain the tank

after each use or daily.

WARNING

CAUTION

Daily Start-Up Procedures

1. Set the Auto-On/Off lever to the Off position.

2. Inspect the air compressor, air hose, and any

accessories/tools being used for damage or obstruction.

If any of these mentioned items are in need of repair/

replacement, contact your local authorized service dealer

before use.

3. Close the drain valve.

4. Check the oil level of the pump.

5. Connect the air hose to the quick connect socket on

the regulator assembly by inserting the quick connect

plug on the air hose into the quick connect socket. The

quick connect socket collar will snap forward and lock

the plug into place providing an air tight seal between

the socket and plug. To release the air hose push the

collar back on the quick connect socket.

6. Plug the power cord into the proper receptacle.

7. Turn the Auto-On/Off lever to the On-Auto position and

the compressor will start and build air pressure in the

tank to cut-out pressure and then shut off automatically.

8. Adjust the regulator to a PSI setting that is needed for

your application and be sure it is within the safety

standards required to perform the task. If using a

pneumatic tool, the manufacturer should have

recommendations in the manual for that particular

tool on operating PSI settings.

9. The air compressor is now ready for use. The following

inflation and cleaning accessories packaged with this

unit should only be operated at maximum pressure

of 90PSI: blow gun, rubber-tapered nozzle, inflation

needles, adapter, and blow gun adapter.

4

���