28

About Your System

E2011

Mem Config

Err

Memory detected, but is
not configurable. Error
detected during memory
configuration.

See "Troubleshooting
System Memory" on
page 142.

E2012

Unusable

Memory

Memory is configured, but
not usable. Memory
subsystem failure.

See "Troubleshooting
System Memory" on
page 142.

E2013

Shadow BIOS

Fail

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 142.

E2014

CMOS Fail

CMOS failure. CMOS
RAM not functioning
properly.

See "Getting Help" on
page 167.

E2015

DMA

Controller

DMA controller failure.

See "Getting Help" on
page 167.

E2016

Int

Controller

Interrupt controller failure. See "Getting Help" on

page 167.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on
page 167.

E2018

Prog Timer

Programmable interval
timer error.

See "Getting Help" on
page 167.

E2019

Parity Error

Parity error.

See "Getting Help" on
page 167.

E201A

SIO Err

SIO failure.

See "Getting Help" on
page 167.

E201B

Kybd

Controller

Keyboard controller
failure.

See "Getting Help" on
page 167.

E201C

SMI Init

System management
interrupt (SMI)
initialization failure.

See "Getting Help" on
page 167.

E201D

Shutdown Test

BIOS shutdown test
failure.

See "Getting Help" on
page 167.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Book.book Page 28 Monday, September 14, 2009 12:57 PM