Physical port setting guidelines, Port class default settings, Table 16 – Dell POWEREDGE M1000E User Manual

Page 77

Advertising
background image

Fabric Watch Administrator’s Guide

57

53-1002752-01

Port class guidelines and default settings

7

Physical port setting guidelines

It is recommended that you use the default settings listed in

Table 16

for most Port class areas.

Consider the Port class to be a superset containing the E_Port, FOP_Port, and FCU_Port
subclasses. If you make a change to a default setting for an area in the Port class, it applies to all of
the subclasses. This is convenient if you have determined that changes you plan to make to the
default settings for the subclasses are the same for certain areas. In this case, you only need to
make the changes to the Port class. Note, however, that if you make a change to one of the
subclasses, that change overrides the Port class setting.

Port class default settings

Table 16

provides default settings for areas in the Port class.

TABLE 16

Port class default settings

Area

Description

Default threshold
settings

Default alarm settings

Threshold state

Cyclic redundancy
check (CRC)

Monitors the
number of CRC
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Invalid transmission
words (ITW)

Monitors the
number of invalid
words transmitted.

Unit: Errors
Time Base: minute
Low: 0
High: 1000
Buffer: 100

Below: 0
Above: 0

Informative
Out_of_range

Class 3 discards
(C3TX_T0)

Class 3 discards
frames due to time
out or destination
unreachable.

Unit: Errors
Time Base: minute
Low: 0
High: 2
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Link loss

Monitors the
number of link
failures.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range

Signal loss

Monitors the
number of signal
loss errors.

Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

State changes (ST)

Monitors state
changes.

Unit: Changes
Time Base: minute
Low: 0
High: 50
Buffer: 0

Below: 0
Above: 0

Informative
Out_of_range

Sync loss

Monitors the
number of loss of
synchronization
errors.

Unit: Errors
Time Base: minute
Low: 0
High: 500
Buffer: 50

Below: 0
Above: 0

Informative
Out_of_range