background image

Error Code

Message Information

MEM0002

Message

Parity memory errors detected on a memory device at location
<

location

>.

Details

The memory is operational. This an early indicator of a possible future
uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0003

Message

Stuck bit memory error detected on a memory device at location
<

location

>.

Details

This is an early indicator of a possible future uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0004

Message

Memory device at location <

location

> is disabled.

Details

The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0005

Message

Persistent correctable memory error limit reached for a memory
device at location(s) <

location

>.

LCD Message

Persistent correctable memory error limit reached for <

location

>. Re-

seat memory.

Details

The memory is operational. This an early indicator of a possible future
uncorrectable error.

Action

Re-seat the memory modules. If the issue persists, see

Getting Help

.

MEM0007

Message

Unsupported memory configuration; check memory device at location
<

location

>.

LCD Message

Unsupported memory configuration. Check memory <

location

>.

Details

The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.

Action

Check the memory configuration. Re-seat the memory modules. If the
issue persists, see

Getting Help

.

MEM0009

Message

Memory device at location <

location

> is throttled.

Details

System performance is degraded.

Action

If unexpected, review system logs for power or thermal exceptions.