Appendix, Summary of microsoft sql server fast track results – Dell PowerEdge R510 User Manual

Page 24

Advertising
background image

Dell R510 Reference Configuration for Microsoft SQL Server® 2008 R2 Fast Track Data Warehouse

Page 22

Appendix

Summary of Microsoft SQL Server Fast Track results

The performance of the system configuration was analyzed with RAID1 for simple, average & complex
query variants with 5, 10, 20, 40 sessions. Various maximum degrees of parallelism (MAXDOP) options
were tested to arrive at the optimal configuration for this workload with MAXDOP=6.

Following table shows the results for simple work load with MAXDOP = 6 (4 disk groups, RAID 1)

Session

Physical I/O throughput

total (MB/s)

Logical I/O throughput

(MB/s)

5 Session

915

1093

10 Session

939

1119

20 Session

919

1224

40 Session

872

1378

The results in the following table are for medium work load with MAXDOP = 6 (4 disk groups, RAID 1)

Session

Physical I/O throughput

total (MB/s)

Logical I/O throughput

(MB/s)

5 Session

704

1009

10 Session

767

1145

20 Session

756

1183

40 Session

650

1038

The following results show the benchmarked rates from memory, physical disks and peak for the
validated solution. These results can be used to compare solutions and choose an appropriate
configuration that meets the throughput requirements.

Benchmark Scan Rate

Logical MB/s

Benchmark Scan Rate

Physical MB/s

FTDW Rated I/O

MB/s

FTDW Peak I/O

MB/s

1204

838

1021

1378

Advertising