Dell PowerEdge SC1430 User Manual

Page 21

Advertising
background image

About Your System

21

General failure

The operating system is unable to
carry out the command.

This message is usually followed by
specific information. Note the
information and take the appropriate
action to resolve the problem.

IDE primary drive

n

not

found

IDE cables are not properly seated, or
drive missing.

See "Troubleshooting an Optical Drive"
on page 106.

Invalid configuration

information - please run

SETUP program

System has detected invalid
configuration.

Remove the RTCST jumper if it is
installed. See Figure 6-1 for the jumper
location.

Invalid NVRAM

configuration, Resource

Re-allocated

System detected and corrected a
resource conflict.

No action is required.

Keyboard Controller

failure

Faulty keyboard controller; faulty
system board

See "Getting Help" on page 123.

Manufacturing mode

detected

System is in manufacturing mode.

Reboot to take the system out of
manufacturing mode.

MEMBIST failure - The

following DIMM/rank has

been disabled by BIOS:

DIMM x Rank y

Faulty memory module(s).

See "Troubleshooting System Memory"
on page 103.

Memory address line

failure at

address

, read

value

expecting

value

Faulty or improperly installed memory
modules.

See "Troubleshooting System Memory"
on page 103.

Memory double word logic

failure at

address

, read

value

expecting

value

Memory odd/even logic

failure at

address,

read

value

expecting

value

Memory write/read failure

at

address

, read

value

expecting

value

Memory tests terminated by

keystroke.

POST memory test terminated by
pressing the spacebar.

Information only.

Table 1-6.

System Messages (continued)

Message

Causes

Corrective Actions