TROUBLESHOOTING GUIDE

Unplug stove before performing any maintenance.

PROBLEM

CAUSE: Too rich air/fuel mixture

? Fire burns with a lazy, orange
flame and/or fuel builds up in the
fire pot. Glass may become dirty.

Make sure glass door is shut and

sealed tightly. If not, adjust door handle
or replace gasket.

Check that ash pan is in place and

sitting flat to assure a proper seal.

Check that exhaust fan is running

and venting properly. If not, check con-
nection and clean or replace.

Moisture content above 15%. Allow fuel to dry or

mix with wood pellets.

Check inside parlor stove and exhaust pipes for

blockage. Tap inside walls of firebox, clean behind
side access plates, clean fire pot and firebox vent
holes above firebrick panel.

Feed rate is too high for fuel, reduce heat setting.

Inadequate combustion air available, add combus-
tion air.

PROBLEM

CAUSE: Fire pot burns out of fuel

? Fire goes out or parlor stove
shuts down. Fuel may stop feed-
ing.

Hopper empty, refill

Auger jams. Remove auger and

clean. (Auger jams can be a problem if
poor quality fuel is used. Or excessive
fines (sawdust, corn cobs or husk) are
found in hopper. Auger jams are evi-
dent when the auger motor runs but no
fuel is delivered.

The TRI-X controller will instruct to push OFF key

until fuel selection is required.

PROBLEM

CAUSE: Auger stops turning

? Fire goes out or parlor stove
shuts down. Fuel may stop feed-
ing.

Feed auger has come loose. Check

to see if auger motor is turning and au-
ger is not.
NOTE: Feed auger is held to the
auger motor by a coupler that is
fastened to the feed auger motor.
Simply slide the feed auger into the
auger housing and rotate until it fits
into the coupler.

Heat sensor. If the operating tem-

perature is too low the parlor stove will
shutdown.

High limit sensor. Evident when parlor stove is ex-

tremely hot. Allow parlor stove to cool for one hour
and restart.

Vacuum switch tripped. Caused by exhaust blower

not running or venting blocked. Check blower, clean
or replace. Clean venting of blockage.

Auger motor not operating. Inspect connection

and replace if necessary.

PROBLEM

CAUSE: Automatic shutdown

? The screen is flashing a fault
message.

Read the fault screen and push the

OFF key.

Most automatic shutdowns occur be-

cause of loss of fire.

The OFF key must be pushed three times to clear

the fault or cycle the power.

The stove is ready for normal operation when

the

[SELECT FUEL TYPE USE MODE kEY] reads

steadily for 30 seconds.

WARNING

NEVER SERVICE OR TOUCH THE FEED AUGER WITH
THE STOVE PLUGGED IN.