Chapter 5: Local Management

5-48

2H28-08R SmartSwitch 2208 User’s Guide

Current Switch Utilization (Read-only)

Shows how much (percentage of processor capacity) of the 2H28-08R is
currently being used.

Peak Switch Utilization (Read-only)

Shows the peak percentage of maximum switching capacity, since last
reset.

Reset Peak Switch Utilization (Toggle)

Allows the user to reset the Peak Switch Utilization field. Setting the
switch to YES resets the Peak Switch Utilization field.

5.13.1

Setting the Reset Peak Switch Utilization

To reset the Peak Switch Utilization field, proceed as follows:

1.

Use the arrow keys to highlight the Reset Peak Switch Utilization
field.

2.

Press the SPACE bar to toggle the selection to YES.

3.

Use the arrows keys to highlight the SAVE command at the bottom of
the screen.

4.

Press ENTER. The message “SAVED OK” displays.

5.14

FLASH DOWNLOAD SCREEN

The Flash Download screen, shown in

Figure 5-20

, allows the user to

upgrade the device with a different firmware image.

Before downloading an image to the device, copy the image to the
network TFTP server.

NOTE

The user may also force the download of an image by changing
the position of Switch 6 located inside the device. Refer to

Section C.2.1

, for details.

NOTE

For information about how to set up a workstation as a TFTP
server, refer to the specific workstation documentation.