Appendix c: technical specifications – Country Flame HR-01 User Manual

Page 46

Advertising
background image

Version

2.0b

46

APPENDIX C: TECHNICAL SPECIFICATIONS

Fuel Type:

#2 Yellow Shelled Corn Fuel

Wood Pellet Fuel

Moisture Content: 14% or less (12% preferred)

A.P.F.I. residential fuel

Heat Content: 10,000 Btu/lb*

Heat Content: 8200 BTU/lb

Ash

Content:

3%

maximum Ash

Content:

1%

max

Bulk Density: 40 lb./cubic ft. min

Moisture Content: 8% max

Size:

1/4”

to

3/8”

diameter

1.5” long max

Fines: 1% max through 1/8

th

screen

Hopper Size:

75 pounds corn or 55 pounds wood pellets


Flue Size:

3” or 4” – dependent on the chimney height


Flue Type:

Type L or PL (

double wall vent)

Type L or PL (

single wall stainless steel liner)


Air Inlet:

1 1/2” Sch 40 Black Iron pipe


Auger Type:

1

1/8”

cup Auger Feed System


Controls:

Electronic Integrated Feed Rate/Blower Speed Controls


Electrical:

120 Volts, 3 Amperes, and 60 Hz


Measurements:

UNIT

BODY

HEIGHT

22.75”

HEIGHT

ON

PEDESTAL

33.75”

HEIGHT ON LEGS

31.25”

UNIT WIDTH (REAR)

25.5”

WIDTH

AT

WIDEST

POINT

30.75”

UNIT DEPTH

24.5”


Weight :

STOVE

WEIGHT 400


Clearances:

UNIT

TO

SIDEWALL

2”

UNIT TO BACKWALL

1”

UNIT

CORNER

TO

DIAGONAL

WALL

1”

TOP TO COMBUSTIBLE

8”

TOP

TO

CEILING

(Alcove)

8”


Shroud Measurements:

*BTU/lb can vary depending on the moisture content of the corn.