Propane cabinet heaters, Warning, Caution – ProTemp PT-18-PCH-A User Manual

Page 2: Page 2, Safety information

Advertising
background image

Page 2

Pinnacle Products International, Inc. Propane Cabinet Heater User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A FUEL SOURCE

Propane

Cabinet Heaters

FIRE, BURN, INHALATION, AND
EXPLOSION HAZARD. KEEP

SOLID COMBUSTIBLES, SUCH AS BUILDING
MATERIALS, PAPER OR CARDBOARD, A
SAFE DISTANCE AWAY FROM THE HEATER
AS RECOMMENDED BY THESE INSTRUC-
TIONS. NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR
AIRBORNE COMBUSTIBLES, OR PRODUCTS
SUCH AS GASOLINE, SOLVENTS, PAINT
THINNERS, DUST PARTICLES OR UNKNOWN
CHEMICALS.

If the information in this manual is not
followed exactly, a fire or explosion may

result causing property damage, personal injury or loss of
life.

- Do not store or use gasoline or other flammable vapors

and liquids in the vicinity of this or any other appliance.

- An LP cylinder not connected for use shall not be stored

in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS:

- Do not attempt to light heater
- Extinguish any open flame
- Shut off gas to heater
- If odor continues, contact your local

gas supplier or fire department.

- Do not touch any electric switch, do

not use any phone in your building

- Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions

- If you can not reach your gas supplier,

call the fire department

- Service must be done by a qualified

service agency or the gas supplier

Do not operate this heater until you
have read, and thoroughly understand

these safety and operating instructions.
Only persons who can read and understand these
instructions should use or service this heater.
Do not direct heater discharge towards another LP
cylinder unless it is at least 20 feet from the heater.

WARNING

California Residents:

Combustion by-products

produced when using this product contain carbon
monoxide, a chemical known to the state of California to
cause cancer and birth defects (or other reproductive
harm).

WARNING

WARNING

Safety Information

This heater is designed and approved for use as a con-
struction heater in accordance with ANSI Z83.7-2011/CSA
2.14-2011. Other standards determine the use of fuel
gases and heat producing products for specific uses.
Check with your local fire safety authority if you have
questions about applications. This infrared heater’s
intended use is primarily for the temporary heating of
buildings under construction, alteration or repair.

Infrared-fired means that all of the combustion products
enter the heated space. This heater is rated at 98%
combustion efficiency, but still produces small amounts of
carbon monoxide. Carbon monoxide is toxic. Humans
can tolerate small amounts of carbon monoxide, and
caution should be taken to provide adequate ventilation.
Failure to provide adequate ventilation in accordance with
this manual could result in death. Early signs of carbon
monoxide poisoning resemble the flu.

- The symptoms of inadequate ventilation are:

* headache * dizziness * burning of the nose and eyes

* nausea * dry mouth * sore throat

- If the heater is being used in the presence of others, be

sure to inform them of the proper safety precautions,
operating procedures and the hazards involved. Some
people are more affected by carbon monoxide than
others. These are pregnant women, people with heart
or lung disease or anemia, those under the influence of
alcohol or at high attitudes.

- Use 20 lb. LP cylinders only.
- Check the heater thoroughly for damage before each

use. DO NOT operate a damaged heater.

- DO NOT modify this heater or operate a heater that has

been modified from it’s original state. Modifying this
heater will void your warranty.

- Keep children and animals away from heater.
- Always set heater on a stable, level surface and use the

caster locks to prevent movement of the heater.

- NEVER use heater in occupied dwellings without

proper ventilation.

- Operate in a manner that heater will not be exposed

directly to rain or dripping water.

- Keep heater area free from combustible materials such

as gasoline, paint thinners and other flammable vapors
and liquids. Dust is combustible. Do not use heater in
areas of high dust concentration.

- ALWAYS maintain proper distance from combustibles.

Minimum clearance from Combustibles:

TOP SIDES FRONT

24” 12” 72”

WARNING! This heater is not intended for residential use.

NOT FOR HOME OR 
RECREATIONAL USE.

WARNING

This is an unvented portable heater. It
uses air (oxygen) from the area which it

is used. Ample combustion and ventilation air must be
provided. See VENTILATION page 4.

CAUTION

Advertising