Propane tank top heaters, Page 4, Connecting heater to lp cylinder – ProTemp PT-47-TTC User Manual

Page 4

Advertising
background image

Page 4

Pinnacle Products International, Inc. Tank Top User’s Manual

NEVER LEAVE HEATER

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A FUEL SOURCE

Propane

Tank Top Heaters

Connecting Heater to LP Cylinder

Be sure to read and understand all of the Safety Information
in this manual before connecting the heater to the LP
cylinder. Installation must conform to local codes and with
the Standard for the Storage and Handling of Liquefied
Petroleum Gases and ANSI/NFPA 58

Inspect the hose and regulator prior to each use of the heater. If
there is excessive abrasion or wear, or if the hose is cut, replace
it with the proper assembly shown in the parts list prior to using
the heater.

Model PT-16-TTC

1. Be sure that the control knob on the regulator is in the “OFF”

position.

2. Line up the threads on the Fuel Connector Nut with the

threads on the LP cylinder valve. Turn Fuel Connector Nut
counterclockwise to tighten. Use a wrench to fully tighten the
nut, being careful not to overtighten.

3. Slowly open the LP cylinder valve.

4. Check all connections for leaks using a 50/50 mixture of dish-

soap and water. Any bubbles appearing show a leak. Remove
and reconnect the Connector Nut to the valve.

Models PT-32-TTC & PT-47-TTC

1. Be sure that the control knob on the regulator is in the “OFF”

position.

2. Line up the slots in the tank collar bracket with the tank collar

ring and slide into place. Be sure the mounting knob is to the
outside, and tighten.

3. Line up the threads on the Fuel Connector Nut with the

threads on the LP cylinder valve. Turn Fuel Connector Nut
counterclockwise to tighten. Use a wrench to fully tighten the
nut, being careful not to overtighten.

4. Slowly open the LP cylinder valve.

5. Check all connections for leaks using a 50/50 mixture of dish-

soap and water. Any bubbles appearing show a leak. Remove
and reconnect the Connector Nut to the valve.

6. Do not direct heater discharge towards any propane cylinder

located within 20 feet of the heater.

Swivel

Bracket

Connection Hose

Tank Collar Bracket

Mounting Bolt
Knob

Wing Bolt

Plane Washer

Figure 3. Perspective view of PT-47-TTC

Figure 4. 47TTC Burner Head Options

Advertising