Convection Heater User’s Manual

Pre-Lighting Instructions

ASSEMBLY
1. Slide upper housing straight up an off of lower housing, and

remove all of the packed items from inside heater.

2. Remove all packaging protecting heater during shipping.

Retain plastic caps covering inlet and regulator hose for
storage

3. Save carton and packing materials for later storage.

4. Inspect heater closely for any damage that may have occurred

during shipping. If there is any damage, return the heater to
the place of purchase.

5. Attach 4 (four) of the phillips head screws to the bottom row of

holes in the lower housing (see Figure 3).

6. Slide upper housing over lower housing, lining up the four

remaining screw holes. Insert 4 (four) phillips head screws and
tighten securely (See Figure 4).

7. Follow all Safety Information on pages 2-4.

CONNECTING THE LP CYLINDER

ALL NEW LP CYLINDERS MUST BE PURGED BEFORE
THE FIRST FILLING.

Purging and filling of LP cylinders must
be performed by personnel who have

been thoroughly trained in accepted LP gas industry
procedures. Failure to follow these instructions may result
in ex plosion, fire, severe personal injury or death.

- To connect hose and regulator assembly, rotate fitting on

hose/regulator COUNTERCLOCKWISE into threads on tank
valve (see Figure 5). Be sure to tighten firmly. Important: Be
sure to position the regulator so that the regulator is horizontal,
also as shown in Figure 5.

- To connect to heater inlet, rotate clockwise and tighten firmly

with a wrench

NOTE:

Once the gas connection has been made, air may be

trapped in the gas line. Before lighting the heater it will be neces-
sary to purge any air trapped in the line. Once this is done the
heater will light and operate normally. Purging the gas line will be
necessary every time the gas cylinder is replaced.

CHECKING FOR LEAKS

- To check for leaks, make up a 50/50 solution of dish soap and

water. Apply this solution to all gas connections. If bubbles
appear, there is a leak. If a leak is found, turn off the gas sup-
ply, and re-connect the leaking connection. If the leak persists
after several tries, contact Pinnacle Customer Service at 215-
891-8460.

- The installation of this heater must meet all local codes and/or

gas utility requirements. In the absence of local codes, the
National Fuel Code ANSI Z223.1 should be followed.

- The minimum clearances to any combustible construction

materials must be maintained at all times (See Page 3).

Figure 5: Connecting the Hose to Heater Inlet

NEVER LEAVE HEATER UNATTEND-

ED WHILE BURNING, OR WHILE

CONNECTED TO A FUEL SOURCE

Figure 3: Removing Upper Housing

Support Screws
in place

Phillips screws

Figure 4: Assembly screw placement

WARNING

Review and understand all of the
warnings in the Safety Information

section of this manual.

WARNING

Advertising
This manual is related to the following products: