Troubleshooting – RearviewSafety RVS-770616N User Manual

Page 24

Advertising
background image

REAR VIEW SAFETY

24

Troubleshooting

Monitor Display Blue Screen & Displays No Signal

Do a hard reset, unplug all
cables and power cables from
multiplexer (silver box) leave
out for 1 minute and then
re-connect them.

Check to ensure that the con-
nection to the camera is tight.

Verify camera cable is plugged
into port labeled Backup Camera

Verify that the blue positive
trigger on power harness is
put to power 12v+.

If the problem still persists,
verify that alternate ports
work. If alternate ports do not
work, remove Blue Trigger wire
from 12V+ and select alter-
nate channels.

Monitor Will Not Power-Up (no backlight on power button)

Check fuse

Check 12v+ to monitor

Check ground connection

No Image On Screen

Verify camera is on correct
camera input

Verify cable is connected to
monitor

Verify camera is connected to
cable

Connect known working
camera and cable to monitor.

Verify Blue trigger is receiving
power

Audio on Camera

Verify chosen camera has audio

Verify volume setting

Confirm that the Blue audio
trigger is connected to 12v+

Advertising