If the gage contacts the top of the valve stem and does not touch the rocker shaft, as
shown in Figure 3, add a corresponding amount of shims between the stand and the
cylinder head. This will raise the rocker stand and shaft to the correct height.




After all of the shaft heights have been set, install the stands to the head and

torque the bolts to 55/65 ft-lbs. The outside exhaust stands have been set-up to index on
the notch in the intake stands to keep them from rotating at high rpm's. Take care to be
sure that the exhaust stands are held snug against the intake stands while tightening the
stand bolts.