Taylor-Wharton EF-1000 User Manual

Page 8

Advertising
background image

BT-472 Rev. B

8

PIPING CIRCUITS


The following paragraphs describe the operation of the piping circuits of the system. The descriptions refer to the main
components of each circuit and are grouped by function. Reference the piping schematic below and in the general
arrangement drawing for the component designations. These component and circuit descriptions should be understood
before attempting operation.

Legend

CN-1

Connection, Liquid Fill / Withdrawal

CV-1

Check Valve, Pump/Top Fill

CN-2

Connection, Full Trycock & Vent

CV-2

Check Valve, In Line

CN-3

Connection, Pump / Top Fill

LI-1

Liquid Level Gauge

CN-4

Connection, Gas Withdrawal

VC-1

Vaporizer Coil

V-1

Valve, Liquid Fill / Withdrawal

PI-1

Pressure Gauge

V-2

Valve, Full Trycock / Vent

PBC-1

Pressure Building Coil

V-3

Valve, Gas Withdrawal

PCV-1

Pressure Building Regulator

V-4

Valve, Pressure Building

PCV-2

Economizer Regulator

V-5

Valve, Pressure Builder Isolation

SV-1**

Safety Valve

V-6

Valve, Economizer Isolation

SV-2

Safety Valve

V-7

Valve, Low Pressure Isolation

SV-3

Safety Valve

V-8

Valve, High Pressure Isolation

R-1**

Inner Container Safety Disc

V-9

Valve, Pressure Equalization

R-2

Outer Casing Safety Disc

V-10

Valve, Manual Ball

FSV-1*

Fill Stop Valve

*

For use with delivery vehicle equipped with automatic filling system, i.e. Taylor-Wharton

Express Cryogenic Delivery System.

** Option available for Dual Safeties/Rupture Disc with Diverter Valve.

Figure 1: System Piping Schematic

Advertising