INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware. The installation surface must be
smooth and flat. If installing into drywall (Figure 1),
drill 5/32" holes and use anchors provided. For
pre-wired installations (as in new home construction),
it may be mounted to a single gang box (Figure 2).
NOTE: After installation, a green or amber indicator
light behind the cover will indicate proper connection.
If not lit, the Lock and Light features will not function
(reverse wires to correct).

1. Strip 7/16" of insulation from one end of bell wire

and connect to the two screw terminals on back of
door control by color: white wire to WHT and
white/red wire to the RED (Figure 3).

2. Remove white cover by gently prying on a side

corner near the top of the cover with a small flat
head screwdriver (Figure 4). Fasten with
6ABx1-1/4" self-tapping screws (drywall
installation) or 6-32x1" machine screws (into gang
box) as follows:

• Drill and install bottom screw, allowing 1/8" to

protrude above wall surface.

• Position bottom of door control on screw head

and slide down to secure. Adjust screw for snug
fit.

• Install top screw with care to avoid

cracking plastic housing. Do not overtighten.

• Insert bottom tabs and snap on cover.

NOTE: The push bar may stick if the door control is
not mounted on a smooth surface. If a click is not
heard when pressing the push bar, loosen the two
mounting screws or relocate the door control to a
smoother surface.

3. (Standard installation only) Run bell wire up wall

and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.

4. Strip 7/16" of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals as
follows: white to white and white/red to red
(Figure 5).

NOTE: When connecting multiple door controls to the
opener, twist same color wires together. Insert wires
into quick-connect holes: white to white and red/white
to red.

5. Use tacks or staples to permanently attach

entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.

NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor Instructions
beginning on page 21.

WHT

RED

Bell Wire

Terminal
Screws

Bottom Mounting Hole

Top Mounting Hole

Dry Wall Anchors

Insulated
Staples

Screw 6AB x 1-1/4"
(drywall installation)

Screw 6-32 x 1"
(gang box installation)

HARDWARE SHOWN ACTUAL SIZE

Figure 2

To Replace
Insert Bottom Tabs First

PRE-WIRED INSTALLATION

24 Volt
Bell Wire

LOCK

LIGHT

LOCK

LIGHT

To Replace
Insert Bottom Tabs First

Figure 1

STANDARD
INSTALLATION

Single
Gang Box

Figure 3

MULTI-FUNCTION
DOOR CONTROL (BACK)

Figure 5

To release wire, push in tab
with screwdriver tip

Door Control
Connections

7/16"

Strip wire 7/16"

Red

Grey

White

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet, and away
from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

WARNING

CAUTION

WARNING

WARNING

KG

1

3

9

7

5

KG

1

3

9

7

5

Advertising