background image

4. Select Gated from the

Ext. Clock Type

drop-down list.

5. Set the Universal Library

EXTCLOCK

option with

cbAInScan()/AInScan

for the slave

UMDAS 0802DA to

enable pacing from the master USB device.

This InstaCal option does not affect internally paced acquisition. It only affects scans that use the

EXTCLOCK

option.

An example of a master/slave configuration is shown here.

Slave

P

Master

UMDAS 0802DA

Slave

UMDAS 0802DA

SYNC pin

pin 19

For the slave

UMDAS 0802DA,

Set the Universal Library

option

with .
This configures the SYNC pin on the slave
unit for input and enables pacing from the

master

UMDAS 0802DA.

EXTCLOCK

cbAInScan()/AInScan()

Figure 3-14. Configuring for synchronous data acquisition

When you are operating one

UMDAS 0802DA, do not set the

EXTCLOCK

option unless you are using an external

clock for A/D pacing.

3-12

UMDAS 0802DA User's Guide Functional Details