Water quality requirement – Cleveland Range 42-CKGM-200 User Manual

Page 2

Advertising
background image

(NOT TO SCALE)

SECT.

III

PAGE

20

1007

Litho in U.S.A

Right - 6”, Left - 6”, Rear - 6” (12”

on control side if adjoining wall or

equipment is over 30” high for

service access)

For use in non-

combustible locations.

Contact factory for

variances to clearances

1 1/2” IPS common drain.

Do not connect other units

to this drain.

Do not use PVC pipe for

drain.

NOTES:

**DO NOT CONNECT TO GFI OUTLET. CLEVELAND RANGE RECOMMENDS GAS FIRED 120 VOLT STEAMERS BE HARD WIRED DIRECTLY TO ELECTRICAL SYSTEM.

Cleveland Range reserves right of design improvement or modification, as warranted.

Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.

Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, NSF and CSA (AGA, CGA).

ACTUAL CAPACITIES:

Kettle 6 gallons/23 liters or 192, 4 oz. servings.

• Other size servings may be calculated.

Each compartment has capacity for:

• Three, 12˝ x 20˝ x 2

1

2

˝ or six, 12˝ x 20˝ x 1˝

deep Cafeteria Pans.

WATER QUALITY REQUIREMENT

The recommended minimum water quality stan-

dards whether untreated or pre-treated, based

upon 10 hours of use per day, and a Daily

Blowdown, are as follows:
TOTAL DISSOLVED

SOLIDS

less than 60 parts per million

TOTAL ALKALINITY less than 20 parts per million

SILICA

less than 13 parts per million

pH FACTOR

greater than 7.5

CHLORINE

less than 30 parts per million

Consult a local water treatment specialist for an on

site water analysis for recommendations concerning

steam generator feed water treatment (if required),

in order to remove or reduce harmful concentrations

of minerals. The use of highly mineralized water will

mean that more frequent servicing of the steam

generator will be necessary. The fact that a water

supply is potable is not proof that it will be suitable

for the generator.

5.0 Amps
** Do not connect to GFI

outlet. See note below.

Advertising