Important Safety Instructions & Guidelines

Risk to Breathing

Risk of

Electrical Shock

Risk of

Explosion or Fire

Avoid using the air compressor in confined areas. Always have adequate space

(12 inches) on all sides of the air compressor. Also keep children, pets, and others out
of the area of operation. This air compressor does not provide breathable air for anyone
or any auxiliary breathing device. Spraying material will always need to be in another
area away from the air compressor to not allow intake air to damage the air compressor
filter.

Never utilize the air compressor in the rain or wet conditions. Any electrical issues or
repairs should be performed by authorized personnel such as an electrician and should

comply with all national and local electrical codes. The air compressor should also have
the proper three prong grounding plug, correct voltage, and adequate fuse protection.

Never operate the compressor near combustible materials, gasoline or solvent vapors.
If spraying flammable materials, locate the air compressor at least 20 feet away from

the spray area. Never operate the air compressor indoors or in a confined area.

Risk of Bursting

Always drain the air compressor tank daily or after each use. If the tank develops a leak,
then replace the air compressor. Never use the air compressor after a leak has been
found or try to make any modifications to the tank. Never modify the air compressor's

factory settings which control the tank pressure or any other function.

Specifications

Pump ..................................................Oil-lube direct drive

Motor Induction .................................. 1.5 HP max developed,

1HP running

Bore ................................................... 1.65"

Stroke.................................................. 1.26"

Voltage Single Phase.......................... 120 VAC

Glossary

CFM: Cubic feet per minute.
SCFM: Standard cubic feet per minute; a unit of measure

for air delivery.

PSIG: Pounds per square inch gauge; a unit of measure

for pressure.

ASME: American Society of Mechanical Engineers.
California Code: Unit may comply with California Code

462 (I) (2)/ (M) (2).

Cut-In Pressure: The air compressor will automatically

start to refill the tank when the pressure drops
beiow the prescribed minimum.

Duty Cycle

This is a 50% duty cycle air compressor. Do not run the air

could damage the air compressor.

Minimum Circuit Requirement ,.. .15 Amps

Air Tank Capacity ..............................3 Gallons

Cut-in Pressure.................................. 95 PS I
Cut-out Pressure................................125 PS I

SCFM @ 90 PSI ............................... 2.4

Cut-Out Pressure: The point at which the motor stops

when the tank has reached maximum air

pressure.

Code Certification: Products that bear one or more of

the following marks: UL, CUL, ETL, CSA, have

been evaluated by OSHA-certified independent
safety laboratories and meet the applicable
Underwriters Laboratories Standards for Safety.