Maintenance, Acaution, Operation maintenance – Craftsman 875.19119 User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

OPERATION

MAINTENANCE

USING QUICK CHANGE RETAINER

1. Disconnect air supply and remove all accessories.

2. Thread quick change chisel retainer onto end of

barrel.

3. While pushing end of spring to side of the tool, insert

a standard .401" taper shank chisel into barrel and
allow spring tension to rest against chisel. Make sure
chisel collar is between barrel and retaining part of
spring.

4. Remove chisel by pushing spring to side of tool and

pull chisel out of barrel.

5. Always hold chisel to work surface before operating

tool.

'Spring Retainer

Air inlet

’ Regulator

Figure 2 - Tool Diagram

Place chisel against work surface and pull trigger in

short bursts until chisel sets in work. Use both hands to

hold hammer for better control.

Lubrication

An in-iinefiiter-reguiator-lubricator{fig 1) is

recommended as it increases too! life and keeps the

tool in sustained operation. The in-iine lubricator should

be regulariy checked and filled with air tool oil. Proper
adjustment of the indine lubricator is performed by
placing a sheet of paper next to the tools exhaust
ports and holding the throttle open approximately 30
seconds. The lubricator is properly set when a light
stain of oil collects on the paper. Excessive amounts of
oil should be avoided.

In the event that it becomes necessary to store the

tool for an extended period of time (overnight, weekend,

etc.), it should receive a generous amount of
lubrication through the air inlet (fig 2). The tool should
be run for approximately 30 seconds to ensure oil has
been evenly distributed throughout the tool. The tool
should be stored in a dean and dry environment.

Recommended lubricants:

Use air tool oil or any

other high grade turbine oil containing moisture
absorbent, rust inhibitors, metal wetting agents and an

EP (extreme pressure) additive. (See Fig. 2 for

iocation/air inlet).

ACAUTION

Never

operate hammer without a chisel installed and

placed against the work surface. Doing so may result in

personal Injury or damage to the tool.

Sears offers a variety of chisels for this hammer.

(

3

)

Advertising