Stardance direct vent - rear vent gas heaters, Vent termination below grade – Vermont Casting SDDVRBS User Manual

Page 18

Advertising
background image

18

Stardance Direct Vent - Rear Vent Gas Heaters

20012950

10.Install the vent terminal. (Fig. 28) Guide the inner

and outer vent termination collars into the adjacent
pipes. Double check that the vent pipes overlap the
collars by 2”. Fasten the termination to the wall with
the screws provided, and caulk the joint with weath-
erproof sealant.

11.Install Charcoal Gray Pipe Rings (#7FSDRG) or Pol-

ished Brass Pipe Rings (#7FSDRP) at pipe joints, if
desired.

ST217

install wall terminal

12/6/99 djt

Seal Both Termi-

nal Ends

Caulk Plate Joint with

Weatherproof Sealant

ST217

Fig. 28 Install the vent terminal.

Vent Termination Below Grade

Install Snorkel #7TDVSNORK when it is not possible
to meet the required vent termination clearances of 12”
(305 mm) above grade level. The snorkel kit will allow
installation depth of down to 7” (178 mm) below grade
level. The seven inches is measured from the center of
the horizontal vent pipe as it penetrates the wall. If the
venting system is installed below grade, a window
well must be installed with adequate and proper
drainage.
(Fig. 29)

ST218a

Pinstar

install snorkel

10/11/00 djt

Waterproof Seal

Around Pipe

Firestop

Drain

4” Clearance

Snorkel

Termination

Cap

Wall Screws

and Anchors

ST218a

Gravel

Fig. 29 Snorkel kit installation.

Window Well

NOTE: Be sure to maintain side wall clearances and
vent run restrictions. Refer to Figures 3 through 11.
1. Establish the vent hole through the wall.
2. Remove soil to a depth of approximately 16” (400

mm) below the base of the snorkel. Install a window
well (not supplied). Refill the hole with 12” (305 mm)
of coarse gravel and maintain a clearance of at least
4” (102 mm) below the snorkel. (Fig. 29)

3. Install the vent system as described on Pages 15-

18.

4. Be sure to make a watertight joint around the vent

pipe joint at the inside and outside wall joints.

5. Apply high temperature sealant around the inner

and outer snorkel collars. Join the pipes and fasten
the snorkel termination to the wall with the screws
provided.

6. Level the soil to maintain a 4” clearance below the

snorkel.

If the foundation is recessed, use extension brack-

ets (not supplied) to fasten the lower portion of the
snorkel. Fasten the brackets to the wall first, and
then fasten to the snorkel with self-tapping #8 x 1/2”
sheet metal screws. Extend the vent pipes out as far
as the protruding wall face. (Fig. 30)

ST219

snorkel detail

12/6/99 djt

Recessed Wall

Sheet Metal

Screws and

Bracket

Wall Screws

and Anchors

Waterproof Seal

Around Pipe

ST219

Fig. 30 Use extension brackets to mount snorkel against
recessed wall.

Firestop

Finishing

Collar

7” Pipe

Wall Plate

Advertising
This manual is related to the following products: