SERVICE AND ADJUSTMENTS

HOW TO REMOVE AN OBJECT FROM THE AIR

INTAKE (Fig. 17 )

If an object is drawn into the unit through the air intake, do

the following:

• Push the switch to the OFF position and disconnect cord

from the power source.

• Remove the vacuum tubes.

• Locate and remove the object{s).

• Inspect the impeller for cracks. If cracked or damaged,

DO NOT use the unit. Have impeller replaced by your
Sears Service Center. DO NOT attempt to replace it

yourself.

STORAGE

Immediately prepare your unit for storage at the end of the

season.

STORAGE INSTRUCTIONS

If your blower Is to be stored for a period of time, clean it

thoroughly before storage. Remove any dirt, leaves, debris,
etc. Store in a clean dry area.

• Discon nect from the power sou rce.

• Clean the entire unit.

• Open Inlet cover and clean any dirt, grass, or debris that

has collected, inspect the blower and vacuum tubes.
Close and make sure cover is latched securely.

Clean afr vents and air Inlet of debris.

Store your unit In a well ventilated area and covered, if
possible, to prevent dust and dirt accumulation. Do not
cover with plastic. Plastic cannot breathe and will induce

condensation and eventual rust or corrosion.

Do not store cord with objects having sharp edges or cor­
ners. Keep cord away from heated surfaces.

Store unit and cord unplugged in a high, cool, dry, indoors
area out of the reach of children.

TROUBLESHOOTING POINTS

TROUBLESHOOTING CHART

SYMPTOM

CAUSE

REMEDY

Unit fails to operate.

• Switch in the OFF position.
• Disconnected from power source.
• Circuit breaker tripped, or fuse

blown.

• Mechanical failure.

Push switch to the ON position.

Reconnect unit to power source.

Reset circuit breaker, or replace fuse.

• Contact your Sears Service/Dept.

Unit vibrates abnormally.

• Mechanical failure.

• Contact your Sears Service/Dept.

Impeller will not turn freely. • Debris in air intake area.

• Mechanical failure.

Clean unit. Remove any debris.

• Co ntact yo u r Sears Service/Dept.

ff situations occur which are not covered in this manual, use care and good judgement.

If you need assistance, contact your Sears Service CenterAyepartment or the

CUSTOMER ASSISTANCE HOTLINE at 1-800-236-6878